MFP250 / 400 / 800
Sequence
76609594EN-MFP-NH-V2.0.docx 35/40
5.3.3
PLC Example for Programming MNC
I_START_ON
Input „Start“ of MNC-AWS3
O_HOME_POS
Output „in home position“ of MNC-AWS3
O_WAIT_POS
Output „in waiting position“ of MNC-AWS3
O_END_CYCLE
Output „End of cycle“ of MNC-AWS3
O_FAULT
Outputs „fault“ of MNC-AWS3 as well as of ISQ-AWS3 in
‘or’-conjunction
O_READY
Output „ready“ of MNC-AWS3 as well as of ISQ-AWS3 in
‘and’-conjunction
M_EVALUATION
PLC memory to activate evaluation of measurement; reset
at end of evaluation
M_PART_IN_POS
PLC memory for part in welding position
M_RELEASE_PLC
PLC memory to release start welding by PLC
M_TRANSPORT_PART
PLC memory to activate part transportation after welding;
reset after transportation
M_END_CYCLE
PLC memory for PLC cycle finished
F_EVALUATION,
F_END_CYCLE, F_FAULT
PLC flank memories