Parameter
Description
Force template
change
Forced template change for every received packet.
State
Enable the selected protocol.
1. It is necessary to calibrate the scanner before using this protocol. See par. 15.6.8.
2. When the
State
option is enabled, you cannot change parameters in the
PROTOCOLS
tab.
15.6.8.2. Holding registers
Read holding registers:
16 bit
15 bit
Scanner 3D Point X * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Scanner 3D Point Y * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Scanner 3D Point Z * 10 (absolute value).
1 bit
Least significant bit.
16 bit
8 bit
The latest counter that was received from the robot (unsigned).
8 bit
Reserved.
16 bit
15 bit
Robot P * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Robot R * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Scanner 2D Point X * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Scanner 2D Point Y * 10 (absolute value).
1 bit
Least significant bit.
Write holding registers:
16 bit
15 bit
Robot X * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Robot Y * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Robot Z * 10 (absolute value).
1 bit
Least significant bit.
16 bit
8 bit
Robot W * 10 (absolute value).
8 bit
Least significant bit.
16 bit
15 bit
Robot P * 10 (absolute value).
1 bit
Least significant bit.
16 bit
15 bit
Robot R * 10 (absolute value).
1 bit
Least significant bit.
16 bit
8 bit
Packet counter (unsigned).
8 bit
Command (unsigned): 0 - no command, 1 - laser ON, 2 - laser OFF. If the
command is the same as previous, nothing will happen.
16 bit
8 bit
Template set selection (unsigned): 0 - Measurement, 1 - Welding. If the
template set number is the same, nothing will happen.
8 bit
Template selection (unsigned). If the template number is the same, nothing will