Standard functions
Compiler – Functions
SCD_TRACYCL
Initializes a data object, whose data is transmitted immediately once.
The object has the following structure:
H+0: Object number
H+1: Number of data bytes and data format
H+2: Number of the variable H" where the data to be sent begins
H+3: Status of the transmission command
The following standard SEW structures are available for the _SBusCommDef state-
ment:
INFORMATION
Prior to transmitting acyclical telegrams, the SBus must also be activated with
_SBusCommOn or _SBusCommState.
MOVIDRIVE
®
B
: The IPOS
plus®
program waits at this command until the message
has been sent, but for a maximum of 10 ms. Users can only monitor whether the tele-
gram has been sent correctly by evaluating the state (H+3) or the expected response.
Instruction type
Standard
structure
Elements
Brief description
_SBusCommDef
SCREC
ObjectNo (H+0)
Object number CAN Identifier (e.g. 1024)
Format (H+1)
Data format
DPointer (H+2)
Number of the variable H" from which point the
received data is stored
There must be 2 variables (H" and H"+1)
reserved for the reception of up to 8 bytes of
data.
SCTRCYCL
ObjectNo (H+0)
Object number (e.g. without CANopen profile as
of 1024
CycleTime
(H+1)
Cycle time [ms]
Offset (H+2)
Offset time [ms]
Format (H+3)
Number of data bytes and data format
DPointer (H+4)
Number of the variable H" where the data to be
sent begins
Result (H+5)
Status of the transmission command:
≥
0
Free bus capacity in % (calculated value of
this unit)
-1
Incorrect cycle time
-2
Too many objects set up
-3
Bus overload
-5
Wrong object number
-6
Wrong length
SCTRACYCL
ObjectNo (H+0)
Object number (e.g. without CANopen profile as
of 1024
Format (H+1)
Number of data bytes and data format
DPointer (H+2)
Number of the variable H" where the data to be
sent begins
Result (H+3)
Status of the transmission command:
0 = Ready
1 = Transmitting
2 = Transmission successful
10 = Transmission error