Table 2-2
MOBY FC configuration scheme
Ladder logic
programming box
Parameters
Data type
Permissible range
Description
MOBY FC
Params_DB
Params_ADDR
Params_DB
Params_ADDR
INT
INT
2 to 32767
0, 300, 600,*...
Parameter data block number for a
MOBY channel (write/read device)
Address pointer in the parameter data
block to the start of a UDT 10
*) These values are exemplary whenever only data structures of the UDT 10 type are arranged in succession. These
values change if UDT 10 is followed by the MOBY command (UDT 20).
Params_DB and Params_ADDR form a pointer to a data structure. This data structure is
defined by calling UDT 10 (English) or UDT 11 (German). A separate data structure must be
defined for each MOBY channel (ASM or write/read device).