Parameterizing
3.1 Parameter data block
FC 45
3-6
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Variable
Description
MOBY U: Range limitation
Normal transmission power
Reduced transmission power
05 hex = 0.5 m
0A hex = 1.0 m
0F hex = 1.5 m
14 hex = 2.0 m
19 hex = 2.5 m
1E hex = 3.0 m
23 hex = 3.5 m
85 hex
8A hex
8F hex
91 hex
99 hex
9E hex
A3 hex
Reduced sending capacity must be set when several
write/read devices are positioned close together or
when data memories which are located in the vicinity
of a write/read device are detected later or not at all.
Disadvantage: The field lobe becomes smaller and
there is less time for communication or positioning
must be more precise.
MOBY D: HF power from 0.5 W to 10 W in increments of 0.25 W
02 hex = 0.5 W
:
10 hex = 4 W (default)
:
28 hex = 10 W
distance_limiting
RF300: 00 hex (reserved)
multitag
MOBY U/D or RF300: Maximum number of MDSs being processed in parallel in the field.
Permissible values: 1
MOBY U: BERO mode; automatic activation/deactivation of antenna field. The "Antenna ON/OFF"
command is superimposed by the BERO mode.
00 hex
01 hex
02 hex
03 hex
=
=
=
=
No BEROs; no write/read device synchronization
One or two BEROs
The BEROs are logically ORed. The field is ON during actuation of
a BERO.
One or two BEROs.
The 1st BERO switches the field on and the 2nd BERO switches
the field off.
If two BEROs exist
and
a field_ON_time is configured, the field is
automatically deactivated if the 2nd BERO does not switch within
that BERO time.
If no field_ON_time is configured, the field remains on until the 2nd
BERO is actuated.
Activate write/read device synchronization via cable connection
(see manual for configuration, mounting and service for MOBY U)
field_ON_control
MOBY D or RF300: 00 hex (reserved)
MOBY U: Time for BERO mode (field_ON_control = 02)
00 hex
01 hex ... FF hex
=
=
Timeout monitoring is deactivated. The 2nd BERO is needed in
order to switch the field off.
1 ... 255s turn on time for the write/read device field.
MOBY D: MDS type
00 hex
01 hex
=
=
I-Code 1 (e.g. MDS D139)
ISO transponder
field_ON_time
RF300: 00 hex (reserved)
reserved0
Reserved
The permissible values of the INPUT parameters are listed in the hardware specifications.