4
Remote Programming Reference
Run Mode Commands
4-69
TRIGger:LEVel<level>(?)
Description
The trigger level command sets the threshold level at the trigger input connector. The trigger level command
will affect the generator only after it has been programmed to operate in interrupted run mode. Modify the
5251 to interrupted run mode using the init:cont off command.
Parameters
Name
Range
Type
Default
Description
<level>
-5 to +5
Numeric
1.6
Programs the trigger level. The value affects the rear
panel input only.
Response
The 5251 will return the present burst count value.
TRIGger:SOURce:ADVance{EXTernal|BUS|MIXed|TTLTrig 0-7 |STAR}(?)
Description
This selects the source from where the 5251 will be stimulated to generate waveforms. The source advance
command will affect the generator only after it has been programmed to operate in interrupted run mode.
Modify the 5251 to interrupted run mode using the init:cont off command.
Parameters
Name
Type
Default
Description
EXTernal
Discrete
EXT
Activates the rear panel TRIG IN input and the front
panel MAN TRIG button. Either a front panel button
push or a legal signal which will be applied to the rear
panel input will stimulate the 5251 to generate
waveforms. BUS commands are ignored.
BUS
Discrete
Selects the remote controller as the trigger source.
Only software commands are accepted while rear
and front panel signals are ignored
MIXed
Discrete
Hardware triggers are ignored until. First output cycle
is initiated using a software command. Subsequent
output cycles are initiated using one of the following:
rear panel TRIG IN, or front panel MAN TRIG button.
TTL Trig 0-7
Discrete
The backplane on the PXI chassis has 8 trigger lines
that can serve as source or target. Normally, these
lines are designated as tri-state lines. The command
converts one of these lines to input. <N> can range
from 0 through 7.
STAR
Discrete
Will select the STAR trigger module, as trigger
source. Select this option only if you have a STAR
module in your system
Response
The 5251 will return EXT, BUS, MIX, TTLTrig 0-7 or STAR depending on the selected trigger source
advance setting.
Summary of Contents for 5251
Page 17: ...List of Figures continued xiv...
Page 35: ...TE5251 User Manual 1 18 This page was intentionally left blank...
Page 37: ...TE5251 User Manual 2 2...
Page 134: ...TE5251 User Manual 3 82 Figure 3 62 Log File Example...
Page 222: ...TE5251 User Manual 4 88 This page was left intentionally blank...
Page 258: ...TE5251 User Manual 5 36 This page was intentionally left blank...
Page 288: ...TE5251 User Manual 6 30 This page was intentionally left blank...
Page 289: ...1 Appendices Appendix Title Page A Specifications A 1...
Page 290: ...TE5251 User Manual 2...