5
IM 701430-51E
• Remote frame
Inter Frame
Space
Recessive
Dominant
REMOTE FRAME
Start of Frame
(1 bit)
S
Arbitration Field
(Std: 12 bit)
(Ext: 32 bit)
Control Field
(6 bit)
CRC Field
(CRC Sequence 15 bit)
(CRC Delimiter 1 bit)
ACK Field
(ACK Slot 1 bit)
(ACK Delimiter 1 bit)
End of Frame
(7 bit)
Interframe
Space or
Overload
Frame
• Standard format and extended format of the data frame and remote frame
S
O
F
R
T
R
I
D
E
r
0
Recessive
Dominant
S
I R
DLC
(4 bit)
Arbitration Field
Data Field
Control
Field
11 bit IDENTIFIER
Standard Format
S
O
F
S
R
R
I
D
E
R
T
R
r
0
Recessive
Dominant
S
I R
DLC
(4 bit)
r
1
Arbitration Field
Data Field
Control
Field
11 bit IDENTIFIER
18 bit IDENTIFIER
Extended Format
• Error frame
Recessive
Dominant
E
ERROR FRAME
Data
Frame
Error Flag
(6 bit)
superposition of Error Flags
(6 to 12 bit)
Error Delimiter
(8 bit)
Interframe
Space or
Overload
Frame
Setting the Identifier Field
• Selecting the condition
Select from the following:
True: Trigger occurs when any of the 4 bit patterns is met.
False: Trigger occurs on a bit pattern other than the four patterns.
• Setting the bit pattern
Four bit patterns can be specified. A trigger is activated on the OR condition (any of
ID1, ID2, ID3, and ID4).
The number of specified bits varies depending on the format type as follows:
Standard format: 11 bits (maximum value is 7FF when set to hexadecimal)
Extended format: 29 bits (maximum value is 1FFFFFFF when set to hexadecimal)
If Identifier is enabled (ON) and all the bits of the ID field is set to X, the trigger does
not occur. The trigger does not occur even when combined with other field and frame
types in this condition. In addition, when X is included in the bit pattern, the trigger
point is set to the end of the Identifier in the same fashion as when 0, 1 is set to the bit
pattern.
2. Setting the Trigger Conditions