26
•
Camera Operation
Type
Enumeration
Values
Sensor
- temperature sensor on sensor board
Mainboard
- temperature sensor on main board
Notes
Changing this value will force the camera to read and update the
DeviceTemperature
Feature.
Name
DeviceTemperature
Display Name
Temperature ( C )
Name Space
Standard
Firmware Release
00
Visibility
Expert
Access
Read-only
Type
Float
Units
degrees Celsius
Values
0 - 100 C
Notes
Depending on the host application (e.g. GUI). This value is a polled value and may
automatically be updated every second. Otherwise the value will only be updated upon
connection or when the temperature selector is changed.
Name
DeviceUserID
Display Name
Device User ID
Name Space
Standard
Firmware Release
00
Visibility
Beginner
Access
Read-Write
Type
String
Values
e.g. ― My Camera
Notes
This feature is automatically saved to the camera's non volatile memory when it is written.
Name
UserSetDefaultSelector
Display Name
[User Set Default Selector]
Power-up Configuration
Name Space
Standard
Firmware Release
00
Visibility
Beginner
Access
Read-Write
Type
Enumeration
Values
None
- no default set is loaded. The camera uses model default values and no factory
calibrated values
Factory
- load factory calibrated defaults
UserSet
x
― load previously saved user set
x
(where
x
is number between 1 and 4)
Notes
Selects the camera configuration set to load and make active on camera power-up or
reset. The camera configuration sets are stored in camera non-volatile memory.
The feature value automatically saved to the camera's non-volatile memory when it is
written.
Name
UserSetSelector
Display Name
User Set Selector
Name Space
Standard
Firmware Release
00
Visibility
Beginner
Access
Read-Write
Type
Enumeration
Values
Factory
- factory calibrated defaults