MeshLinx MWI-5000 User Guide
MESHLINX CONFIDENTIAL
3
set rrm frame duration <duration>
-
set the measurement duration.
get rrm frame –
get the current values.
set rrm noisehistogram interval <interval>
- set the Randomization
Interval.
set rrm noisehistogram duration <duration> -
set the measurement
duration.
get rrm noisehistogram –
get the current values.
set rrm channelload interval <interval>
- set the Randomization
Interval.
set rrm channelload duration <duration> -
set the measurement
duration.
get rrm channelload –
get the current values.
set rrm hiddennode interval <interval>
- set the randomization
interval.
set rrm hiddennode duration <duration> -
set the measurement
duration.
get rrm hiddennode –
get the current values.
set rrm statistics interval <interval>
- set the randomization
interval.
set rrm statistics duration <duration> -
set the measurement
duration.
get rrm statistics –
get the current values
set rrm threshold <threshold> –
set the threshold for the request
to be blocking or non-blocking in seconds.
set rrm reportttl <expiration time> -
report time to live
in the
list, i.e. the expiration time after the measurement timeout in
seconds.
4.2.3.30
4.2.3.31
Quality of Service (QoS)
Qos control
set qos [enable|disable]
– enable/disable 802.11e QOS on Access Point.
set qos qbssload [enable|disable]
–
enable/disable QBSS Load IE.
set qos loadbalance <enable|disable>
Enable/Disable the Load Balance feature.