Component Functions
EN-US · 30.30.01.02237 · 00 · 04/20
55 / 94
0x8D20 to
8D2F
0x8D30 to
8D3F
0x8D40 to
8D4F
0x8D50 to
8D5F
Evacuation time t1 is greater than limit, ejec-
tors #1 to #16
Leakage rate is greater than limit, ejectors #1
to #16
H1 was not reached, ejector #1 to #16
Free-flow vacuum level too high, ejector #1 to
#16
Warning, low
Warning, high
Warning, low
Default
value
-
Unit
-
EEPROM
no
More detailed error code descriptions, causes and remedies can be found in chapter 11.2.
Error Codes (0x0082) (CU Active Errors)
The active error codes for the SCTSi are displayed using individual bits.
Parameter
130 (0x0082) + process data
Description
Active errors of the control unit
Index
16
Data type
uint8
Length
1 bytes
Access
Read only
Value range
Bit 0 = Internal error: data corruption
Bit 1 = Internal error: bus fault
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = Secondary voltage too low
Bit 5 = Secondary voltage too high
Bit 6 = Supply pressure too low (< 1.9 bar) or too high (> 6.3 bar)
Bit 7 = Error in one or more ejectors
Default value
0
Unit
-
EEPROM
no
Error Codes (0x0082) (Ejector Errors)
The active error codes for the Compact terminal SCTSi and ejectors are displayed using individual bits.
Parameter
130 (0x0082)
Description
Errors in ejector
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint8
Length
16 bytes
Access
Read only
Value range
Bit 0 = Measurement range overrun
Bit 1 = Vacuum calibration failed
Default value
0
Unit
-