14
TEC-61231-23 Technical Manualе
PRIZRAK
Table 9. Functions of programmable outputs
#
Function
Description
1
Security state
Emitting a constant level signal while the Alarm is in Security mode
2
Arming pulse
Emitting 0.8 sec pulse when entering the Security mode or triggering AntiHiJack feature.
3
Disarming pulse
Emitting 0.8 sec pulse when leaving the Security mode.
4
Authentication pulse
Emitting 0.8 sec pulse after PIN code is entered or in Maintenance mode (1 second after the ignition has
been turned on).
5
Factory alarm panic
Emitting of a constant level signal while the original alarm system (if installed) is in alarm condition.
6
Beeper panic
Emitting a 30 sec constant level signal in Security mode if one of the main zones (doors, hood, trunk) is
triggered or any sensor is triggered. The signal stops after exiting the Security mode.
7
Horn panic
Emitting a 30 sec pulse signal in Security mode if one of the main zones (doors, hood, trunk) is triggered.
Signal is also emitted when arming/disarming. This function can be used for the vehicles without any
integrated original alarm system. The signal stops when exiting the Security mode. This function can send an
alarm signal to original horn of the vehicle.
8
Doors, hood and trunk
Emitting a constant level signal if any of the preset doors, hood or trunk is triggered.
9
Sensor ignore
Emitting a constant level signal in the Security mode if the trunk is opened via original remote control. The
signal is also emitted for the purposes of Comfort feature. This function can disable sensors to prevent false
alarms.
10
Factory buttons
Emitting a constant level signal when pressing a preset button of the vehicle.
11
Ignition
Emitting a constant level signal when the ignition is turned on (including the engine startup).
12
АСС
Emitting a constant level signal when ACCs of the vehicle (1st key position; for some vehicles it matches the
ignition position) are on. The signal stops only after the key is out of the ignition lock. This function can help
to correctly manage power supply to an accessory alarm system of multimedia system.
13
Engine is running
Emitting a constant level signal when the engine is on.
14
Engine RPM
Emitting an pulse with a pulse frequency in proportion with the engine crankshaft rpm. 1 pulse per second
corresponds with 20 rpm of the crankshaft. The signal helps to evaluate the rpm rather than give an exact
value.
15
Gearbox state
Emitting a constant level signal if transmission handle is in preset position (P, R, N, D1)). For semi-automatic
transmission positions R, N, D 1); for manual transmission only position R.
16
Vehicle is moving
Emitting a constant level signal if the speed exceeds some threshold value (the speed value is different for
each vehicle, but generally it is in the range of 5 to 10 km/h).
17
Front parking sensors control
Emitting a constant signal level in accordance with the preset algorithm of the parking system.
18
Rear parking sensors control
Emitting a constant signal level in accordance with the preset algorithm of the parking system.
19
Movement speed
Emitting a pulse with a pulse frequency in proportion with the vehicle’s speed. 1 pulse per second corresponds
to 1 km/h. The signal helps to evaluate the speed rather than give an exact value.
20
Brake
Emitting a constant level signal when the brake pedal is pressed.
21
Hand brake
Emitting a constant level signal when the vehicle is on hand brake.
22
External lights
Emitting a constant level signal when external lights are on.
23
Timer channel (Comfort)
Timer control channel; 10 to 60 seconds.
24
Diagnostic bus lock
Control of a
noыrmally
closed locking relay, which is cut into the vehicle diagnostics bus. This function is
enabled in Security mode and active CAN bus.
25
Hood is closed pulse
Emitting of 0.8 sec pulse after activation of Security mode provided that the hood is closed (terminal switch
is OFF or not assigned).
26
Parking system LED
This function indicates the parking system status. If parking sensors are operated by "reverse gear” algorithm
or “by reverse gear with an override” algorithm, LED is on when sensors are on. If parking sensors follow
“activated by speed level” algorithm, the LED is on while sensors are disabled
27
External heater control
This function has to be assigned to any digital output. It is a prerequisite to access GSM module menu and
gain control of the preheater.
28
Pulse to imitate closing of
drives door for remote start
Emitting of 1.5 sec pulse simulating the driver leaving the vehicle to switch ACC off.
29
Trunk is open
Emitting of 0.8 sec pulse.
This function has to be assigned to any digital output. It is a prerequisite to access GSM module menu and
gain control of the trunk.
30
Control of an aftermarket
remote start module
Used only with aftermarket remote start module. Emitting a constant level signal to remote start the engine
on engine lauch until engine stop. Signal will be shaped with or without the ESM-250 unit or ingition lock or
start\stop button connection. Function has to be assigned to digital output, afterwards the remote start menu
and commands to control launches in the voice menu will be enabled
31
Accelerator pedal lock
(force to stop)
Stops the vehicle if AntiHiJAck was triggered (according to the "safe lock" settings). Controls a normally open
relay.
32
Close electromechanical
door locks
Emitting a 0.8 sec pulse to close electromechanical door locks
33
Open electromechanical
door locks
Emitting a 0.8 sec pulse to open electromechanical door locks
34
Control of a normally open
relay to control central lock
Used to control circuits that control central lock.
35
Dual wire control of a
Fortin module – "Ground
while running"
Function is used to control a remote start module made by Fortin. Tied with Dual wire control of a Fortin
module – "Start" function.
Attention! Assigning this function to a
programmable input will disable ESM-250 and functions #37,38,39. To
reenable ESM-250 and disabled features - reprogram this function
36
Dual wire control of a
Fortin module – "Start"
Function is used to control unit made by Fortin. Tied with Dual wire control of a Fortin module – "Ground
while running".
Attention! Assigning this function to a
programmable input will disable ESM-250 and functions #37,38,39. To
reenable ESM-250 and disabled features - reprogram this function