15
TEC-61231-23 Technical Manualе
PRIZRAK
#
Function
Description
37
Immobilizer bypass
module (remote start)
Function to enable remote launch on vehicles equipped with start/stop button (without remote start module)
Output operates exactly as corresponding output of ESM-250
38
Start/Stop button
control (remote start)
Function to enable remote launch on vehicles equipped with start/stop button (without remote start module)
Output operates exactly as corresponding output of ESM-250
39
Brake pedal press
(remote start)
Function to enable remote launch on vehicles equipped with start/stop button (without remote start module)
Output operates exactly as corresponding output of ESM-250
40
Single wire iDataLink
module control
Function is used to control unit made by iDataLink.
Attention! Assigning this function to a
programmable input will disable ESM-250 and functions #37,38,39. To
reenable ESM-250 and disabled features - reprogram this function
41
LED to show heater state
If the heater was launched by the system, the LEDs will stay on for heater operation
42
Dashcam activation
Signal is formed: if ignition is on; for 5 minutes after alarm was triggered(warning or alert); if alert was triggered
by phone. If alarm was triggered again while dashcam is active dashcam will work for 5 more minutes.
1)
A
ll handle positions used for forward movement of the vehicle (D, S, M, L, etc.).
Table 10. Programmable input functions
#
Designation
Description of the function
1
Brake lights state
This function is used only if the vehicle CAN bus does not contain data on brake pedal position. In this case
brake light control input is to be connected with brake pedal terminal switch output.
2
Hood state
This function is used if the vehicle CAN bus does not contain data on hood position. In this case hood control is
to be connected with hood terminal switch.
3
Door state
This function is used in exceptional cases, when CAN bus does not contain data on door position (please
see the Integrator files).
4
Central Lock is
closed (status)
This function is used in exceptional cases, when CAN bus does not contain data on Central Lock status
(please see the Integrator files).
5
Central Lock is
open (status)
This function is used in exceptional cases, when CAN bus does not contain data on Central Lock status
(please see the Integrator files).
6
Ignition
The function is used only in cases when the correct data from CAN bus is not available. This situation
may occur when some circuits of the vehicle are blocked. In this case the Ignition control input is to be
connected to the vehicle wire that has a constant level signal when the ignition is on. Connecting this input
does not cancel the ignition analysis via CAN bus. The ignition is considered on when data is received by any
informational channel (CAN bus or analog input)
7
Trunk state control
The function is used in case an alarm is triggered when the trunk is opened via original remote control and/or
keyless access system. In this case Trunk opening control input is to be connected to trunk opening feed control
wire. Input control is available only in Security mode. When a command to open the trunk is detected, the Alarm
ignores external sensor inputs and trunk terminal switch for 5 seconds until the actual opening of the trunk. In 5
seconds after the trunk lid has been closed, sensor inputs and the trunk will be secured.
8
Parking system button
The function controls parking sensors by using accessory button (this may be required if there are no
buttons in the vehicle detected by CAN bus)
9
Heater state
When signal is fed to this input, it means that external preheater is on. Assigning this function to any digital
output is a prerequisite for accessing the GSM module menu and preheater control.
10
Wipers control
The function monitors wipers and makes sure they are disabled. Monitoring is fulfilled if the software neutral
is enabled. The driver is notified by a long audio signal. The signal here means that wipers are enabled.
11
Ignore brake pedal
in remote start (with
alternative remote
start module)
Used with alternative remote start module
12
Shutdown the engine
in remote start
Pulse on input stops or disables remote start
13
Parking brake
The function is used when CAN bus does not contain data on hand brake position.
14
Wake CAN bus
This function is used in exceptional cases (please see Integrator)
15
Hazard lights status
This function is used in exceptional cases (please see Integrator)
16
Trunk state
The function is used when CAN bus does not contain data on trunk status. In this case “Trunk” input has to
be connected to trunk terminal switch output.
17
Digital button
Used to enter PIN code or for other tasks
18
Close central lock
This function is used in exceptional cases (please see Integrator)
19
Open central lock
This function is used in exceptional cases (please see Integrator)
20
Additional sensor input 1 Used to connect additional sensor
21
Additional sensor
input 2
Used to connect additional sensor
22
Engine state in
remote start
Pulse to this input will identify engine state – only in turbo timer, "keep running" or auto launch mode. In
other modes signal from this input is not used, and engine state is taken from the CAN bus (if it is available).
Input has a priority over “Engine was started” signal from CAN bus: system responses only signals from this
input. Input can recognize continuous signals as well as pulse signals.
23
Input to launch
the heater
Signal to this input will launch factory or aftermarket heater. Heater will run as long as the signal is present
24
Input for drivers
door switch
The function is used when CAN bus does not contain data on door position state(please see the Integrator
files)
25
Factory security
system alert
Signal to this input allows to get information about alert state of the factory security system of the vehicle.
If signal is present – Factory security system is in alert state
26
Look for RFID tag
Signal on this input will engage RFID tag search (1min) and authentication. After authentication alarm will disarm
and central lock will open. RFID tag will be looked for 1 minute or until alarm is armed (whichever comes first)
Feature enabled, if "Menu 1" №21 "
RFID tag" set to
"factory remote lock
" или "
factory remote lock in high risk
locations
"; in "Menu 2" option №12 "Authentication" – set to any state except "PIN-code".
27
"Beach mode" code
Used to set "Beach mode".