multiSwitch – user manual
© TOPEX 2008 43
The register and proxy parameters are detailed in the table below:
Proxy parameter name
Significance of register and proxy parameters
update_location
Update online users memory status to database table sip
location
Value 0 = disable, 1 = enable and the default value is 1
proxy
Enable the proxy parameter of multiSwitch. The values
available are 0 = disable, 1 = enable.
This parameter must
be always enabled!
record_route 1
Must be always enabled
. If enabled all dialog messages
will go through the SIP proxy
0=disable, 1=enable, default 1
register_auth 0
Allows the register of SIP users. By default is disabled.
0=disable, 1=enable, default 0
invite_auth 0
Authenticate incoming invite request on UA
0=disable, 1=enable, default 0
default_register_expire 600
default_subscribe_expire 600
default_publish_expire 600
Timer in seconds. It is used if the incoming
REGISTER/SUBSCRIBE/PUBLISH don't have an expire
header/parameter in request
forced_register_expire 600
forced_subscribe_expire 600
forced_publish_expire 600
Timer in seconds. It forces the expire refresh interval to
value configured here. It has higher priority than
default_xxx_expire
tos
Type Of Service, integer value, default 0. The ToS
parameter represents a field in an IP packet header that
specifies the service level required for the packet
heartbeat 9001
Remote heartbeat UDP port where the KEEP_ALIVE
messages are sent
0=disable sending of KEEP_ALIVE messages
default 0
The same port must be configured also in
application at
app_port
or
second_app_port
redundancy client/server
192.168.1.193:8001
Configure the ip:port of server redundant equipment. One
equipment must be client and the other one must be server.
A TCP socket is used; one equipment is server and the
other one is client
user_redirect 0
Enable a SIP user to redirect (forward) a call from SIP
phone instead using call forward setting from SSW
0=disable, 1=enable, default 0
register_client_random 0
Enable the random registration of clients
0=disable, 1=enable, default 0
database_row_chunk 50
Activates the number records read from the data base at
once. For instance the records can be sipusers,
sipuseralias, etc
It must be an integer number between 10 and 500. The
default value is 50
user_agent
String value, default version of centrala application (run
centrala -v to see version)
max_call_time 3600
Max call time for proxy calls. If this value is reached the
proxy will cut the current call. The time is set in seconds
0=disable; default 0
session_expires 1800
The time in seconds after which a session expires. It must
be in the interval 90 and 7200. The default value is 1800
min_session_expires 90
The minimum time in seconds after which the session
expires. It must be in the interval between 90 and 7200. The
default value is 90
[credentials]
192.168.1.100 306 306
Credentials used for outgoing INVITE authorization on User
Agent
- realm(ip/dns_name) user_name password