Debug Support
8-34
Copyright © ARM Limited 2000. All rights reserved.
If false matches can occur during changes to the watchpoint registers, caused by old
data in some registers and new data in others, then you must:
1.
Disable that watchpoint unit using the control register for that watchpoint unit.
2.
Change the other registers.
3.
Re-enable the watchpoint unit by rewriting the control register.
8.12.1
Further reading - debug in depth
A more detailed description of the ARM9E-S debug features and JTAG interface are
provided in the ARM9E-S Technical Reference Manual, Appendix D Debug in Depth.