Section 4: Programming Options
will restart trouble beeps. For troubles that have been
silenced but are still present, trouble beeps restart daily at
7am.
Default:
Disabled
Valid range:
Enabled, Disabled
Burglary Bell Time-out
This option determines the length of time the system siren
sounds for. System tampers follow this timer, but Fire alarms
and keypad buzzers do not.
Default:
4 Minutes
(Note: Burglary Bell Time-out shall be 4 minutes for
UL/ULC)
Valid
range:
0 to 255 Minutes
Fire Bell Time-Out
This option determines the maximum activation time for fire
alarm sirens. Each partition has a dedicated Fire Bell Time-
out timer.
Fire Bell Time-out takes priority over Burglary Bell Time-out.
Default:
5 Minutes (Note: Fire Bell Time-out shall be 5 minutes for
UL/ULC)
Valid
range:
0 to 255 Minutes
Audible Panic
This option is used to set internal buzzer behavior when the
Panic key is pressed. When set to Audible, pressing the
Panic key causes the buzzer to sound a series of 3 beeps to
acknowledge the alarm. The buzzer then sounds a steady
tone for the length of the bell time-out or until an access
code is entered.
When set to Silent, pressing the Panic key causes the
buzzer and the bell output to remain silent, but the alarm is
still transmitted (if programmed).
Default:
Silent
Valid range:
Audible, Silent
Access Code Required For Bypassing
When this option is enabled, an access code is required to
view the zone bypass menu.
When this option is disabled, the zone bypass menu is
accessible to anyone.
Default:
Disabled
Valid range:
Enabled/Disabled
RF Jam
When this option is enabled, the alarm panel detects and
reports continuous wireless signals that could interfere with
the operation of the alarm system.
UL: The iotega detects and reports continuous RF inter-
ference using UL 20/20 requirements for wireless jam detec-
tion (20 seconds of continuous jam detection is required).
Default:
Disabled (Note: RF Jam shall be enabled for UL/ULC
applications)
Valid
range:
Disabled, UL
Installer Access Window Permission
When this option is enabled, the installer is given access to
the panel’s programming sections for a 4-hour window, or
until the install has been finalized.
When this option is disabled, the installer can access the
panel’s programming sections at any time.
This option is controlled by Level 1 users.
Default:
Enabled
Valid range:
Enabled, Disabled
Ethernet IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
Ethernet IP Subnet
This is the resolved value based on the DHCP address
assignment.
Default:
255.255.255.000
Valid range:
Read-only
Gateway IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
DNS 1 IP Address
This is the resolved value based on the DHCP address
assignment.
Default:
000.000.000.000
Valid range:
Read-only
- 18 -