Section 4: Programming Options
Armed LED Power Save Option
This option is used to control the Armed LED on/off state. If
enabled, the Armed LED does not illuminate when the sys-
tem is armed to conserve battery life.
Default:
Disabled
Valid range:
Read-only
Auto Scroll Open Zones Option
When this option is enabled, the keypad automatically
scrolls through and displays all open zones.
Default:
Enabled
Valid range:
Read-only
Alarms Displayed While Armed Option
When this option is enabled, the keypad displays alarms on
affected zones while the system is armed.
If disabled, zones in alarm are not displayed while the sys-
tem is armed.
Default:
Enabled
Valid range:
Read-only
Power LED AC Present Option
When this option is enabled, the Power LED illuminates
when the iotega has electrical power.
When disabled, The Power LED illuminates when the iotega
does not have electrical power.
Default:
Enabled
Valid range:
Read-only
Auto Alarm Scroll Option
When this option is enabled, the keypad scrolls auto-
matically and displays all alarms when the bell is active or
when an alarm is in memory while armed.
Default:
Enabled
Valid range:
Read-only
Local Clock Displays 24 Hour Option
When this option is enabled, time is displayed in 24-hour
clock format.
Default:
Enabled
Valid range:
Read-only
Local Clock Display Option
When this option is enabled, the keypad displays the time
and date when not in use.
Default:
Enabled
Valid range:
Read-only
Keypad Lockout Duration
This option displays the length of time that the wirefree
keypad remains locked after the programmed number of
access code attempts has been exceeded.
Default:
5 Minutes
Valid range:
Read-only
4.6.2 User Configuration Options
This section describes programming options for configuring
system users.
User Partition Assignment
This section is used to assign system user 2-100 to an avail-
able partition. Users may be assigned to multiple partitions.
Basic/Standard users may only assign new users to par-
titions they themselves have permission to access.
Default:
1
Valid range:
1, 2, Both
User Access Code (Pin)
This section is used to program a 4-digit code used to
access the panel. Each user requires a code. Duplicate
codes are not permitted.
Default:
Blank
Valid range:
0000 to 9999
User Access Level
Each system user is assigned an access level that determ-
ines the features they can use. All codes are 4-digit decimal
entries. Duplicate codes are not permitted.
The following access levels may be available on your panel:
Installer code:
Has permission to enable WPS mode (to enable local pro-
gramming access to the panel via the installer app).
Basic/Standard User:
Has permission to access basic security functions, including:
l
Arm/disarm
l
Bypass/unbypass zones
- 31 -