11
To resolve the issue:
1.
Verify that the system software image on the switch is correct.
a.
Log in to the switch through the console port and restart the switch. If the system reports
that a CRC error occurs or that no system software image is available during the BootWare
loading process, reload the system software image.
b.
Verify that the system software image in the flash memory is the same size as the one on
the server. If no system software image is available in the flash memory, or if the image size
is different from the one on the server, reload the system software image. Then set the
reloaded system software image to the current system software image.
The system software image in the flash memory is automatically set to the current system
software image during the BootWare loading process.
2.
Verify that the memory is running correctly.
Reboot the switch, and immediately press
CTRL+T
to examine the memory. If a memory fault is
detected, replace the switch.
3.
Verify that no error is reported during the BootWare loading process.
If the memory is running correctly but there are still errors reported during the BootWare loading
process, replace the switch.
4.
If the issue persists, contact H3C Support.
Operating power module failure
Symptom
An operating power module fails.
Solution
To resolve the issue:
1.
Identify the operating state of the power module.
Execute the
display power
command to view the operating state of the power module.
<Sysname> display power
Input Power:132W
PowerID State InPower(W) Current(A) Voltage(V) OutPower(W) Type
1 Absent -- -- -- -- ---
2 Normal -- -- -- -- PSR300-A
Execute the
display alarm
command to view alarm information about the power module.
<Sysname> display alarm
Slot CPU Level Info
1 0 INFO Chassis 1 power 1 is absent.
If the power module is in
Absent
. If the power module is in
Fault
state, go to
2.
Verify that the power module is installed securely.
Remove and reinstall the power module to ensure that the power module is installed securely.
Then execute the
display power
command to verify that the power module has changed to
Normal
state. If the power module remains in
Absent
state, replace the power module.
3.
Verify that the power module is operating correctly.
a.
Verify that the power cord is connected to the power module securely.
<Sysname> display power