User Manual of iSV2-CAN Servo
www.leadshine.com
47
deactivated when the actual bus voltage is lower than Pr7.32 minus Pr7.33
Notice
:
Pr7.33
Name
Regenerative resistance control hysteresis
Mode
P
S
T
Range
1
~
50
Unit
V
Default
5
The external resistance is activated when the actual bus voltage is higher than Pr7.32 plus Pr7.33 and is
deactivated when the actual bus voltage is lower than Pr7.32 minus Pr7.33
Notice
:
4.3 402 Parameters Function
Index
603FH
Name
Error code
-
Structure
VAR
Type
Uint 16
Access
RO
Mapping
TPDO
Mode
ALL
Range
0-6553
5
Default
-
Index
6040H
Name
Control word
Structure
VAR
Type
Uint 16
Access
RW
Mapping
RPDO
Mode
ALL
Range
0-6553
5
Default
0
Bit
15~11
10~9
8
7
6~4
3
2
1
0
Definition
-
-
Halt
Fault
reset
Mode
specific
Enable
operation
Quick
stop
Enable
voltage
Switch
on
Index
6041H
Name
Status word
Structure
VAR
Type
Uint 16
Access
RO
Mapping
TPDO
Mode
ALL
Range
0-0XF
FFF
Default
0
Bit
7
6
5
4
3
2
1
0
Definition
Reserved
Switch on
disabled
Quick
stop
Voltage
output
Fault
Operation
enable
Switch
on
Ready to
switch
on
Bit
15
14
13
12
11
10
9
8
Definition
Reserved
Reserved
Mode
specific
Mode
specific
Position
limit
active
Target
reached
Remote
Mode
specific
Index
605AH
Name
Quick stop option code
Structure
VAR
Type
INT 16
Access
RW
Mapping
-
Mode
ALL
Range
0-7
Default
0
PP, PV Mode
0
:
Stop according to 3506h(Sequence at Servo-off)
,
keeping Switch on disabled
1
:
Stop according to 6084h(Profile deceleration)
,
keeping Switch on disabled
2
:
Stop according to 6085h(Quick stop deceleration)
,
keeping Switch on disabled
3
:
Stop according to 60C6h(Max deceleration)
,
keeping Switch on disabled