User Manual of iSV2-CAN Servo
www.leadshine.com
64
default value. The default values of 6091_01, 6091_02 and 6092_01 are 1, 1 and 10000.
6.4.4 Control Word
The binary representation of the controlword (6040) is as follows:
Bit
15~11
10~9
8
7
6~4
3
2
1
0
Definition
-
-
Halt
Fault
reset
Mode
specific
Enable
operation
Quick
stop
Enable
voltage
Switch
on
Command
Bit7 and Bit0 to Bit3
6040
Value
402 State
machine *1)
7
:
Fault
reset
3
:
Enable
operation
2
:
Quick
stop
1
:
Enable
voltage
0
:
Switch
on
Power off
0
×
1
1
0
0006h
2;6;8
Switch on
0
0
1
1
1
0007h
3*
Switch on
0
1
1
1
1
000Fh
3**
No voltage
output
0
×
×
0
×
0000h
7;9;10;12
Quick stop
0
×
0
1
×
0002h
7;10;11
Operation
disable
0
0
1
1
1
0007h
5
Operation
enable
0
1
1
1
1
000Fh
4;16
Fault reset
Rising
edge
×
×
×
×
0080h
15
× is not affected by this bit state
* indicates that this transition is performed in the device start state
** indicates that it has no effect on the start state and remains in the start state
*1) The state machine switch corresponds to figure 6.1
The definition of bit 8 and bit 6~4 in different operation modes are shown in the following table
Bit
Operation Mode
Profile Position
(PP)
Profile Velocity
(PV)
Profile Torque
(PT)
Homing
(HM)
8
Halt
Halt
Halt
Halt
6
Abs / Rel
-
-
-
5
Change set
immediately
-
-
-
4
New set-point
-
-
Homing
operation start
6.4.5 Status Word
Bit definition of Status Word 6041h.
The binary representation of the statusword (6041) is as follows: