Description
Name
Data type
Adress
Alarm status flag can at any given
time hold a
Alarm status flag
Uint16
30047
combination of values from the
list below. Check
the individual bits to determine
the type of alarms
that are currently triggered. This
flag is automatically
cleared after 5 seconds if the cause
of the alarm
trigger is no longer present.
0x0000 = Not triggered
0x0001 = Tool overheated
0x0002 = Motor drive overheated
0x0004 = Over-current
0x0008 = Under-voltage
0x0010 = Over-voltage
0x0020 = Self-test running
0x0040 = RPM drop
0x0080 = High current
0x0100 = Tool change in progress
0x0200 = Possible tool wiring fault
0x0400 = Factory reset mode
0x0800 = Write protection dis-
abled
Holding registers (F3, F6, F16)
Description
Name
Data type
Address
Max length 19 printable charac-
ters, e.g. “AIMD 749474379001”.
Device name
Char[20]
40001-40010
Speed set-point, not the actual
speed, between 4,000–10,000
RPM.
Speed set-point
Uint16
40011
11
en (original)