60
Manual – DFD11B DeviceNet Fieldbus Interface
6
The Common Industrial Protocol (CIP)
DeviceNet Characteristics
Register object
• The register object is used to access an SEW parameter index.
• Class code: 07
hex
Class
None of the class attributes are supported.
The MOVILINK
®
parameter services are mapped in the nine instances of the register
object. The services "Get_Attribute_Single" and "Set_Attribute_Single" are used for ac-
cess.
As the register object is designed so that INPUT objects can only be read and OUTPUT
objects can be read and written, the options listed in the following table are available for
addressing the parameter channel.
Instance
INPUT OUTPUT
Resulting MOVILINK
®
service with
Get_Attribute_Single
Set_Attribute_Single
1
INPUT
READ parameters
Invalid
2
OUTPUT
READ
WRITE parameters
3
OUTPUT
READ
WRITE VOLATILE parameters
4
INPUT
READ MINIMUM
Invalid
5
INPUT
READ MAXIMUM
Invalid
6
INPUT
READ DEFAULT
Invalid
7
INPUT
READ SCALING
Invalid
8
INPUT
READ ATTRIBUTE
Invalid
9
INPUT
READ EEPROM
Invalid
0
0
I