Programming via OPC UA
10.1 Supported methods/functions
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
119
OPC UA events
RfidScanEventType
Receive "TagEvents".
OPC UA variables (read only)
AntennaNames
Antennas of read point
AutoIdModelVersion
Version of the supported AutoID model
DeviceInfo
Information on the communication module (e.g. information on the device)
DeviceLocationName
Information on the communication module (e.g. information on the location)
DeviceManual
URL to the manual for the communication module
DeviceName
DisplayName of the read point
DeviceRevision
Reserved
DeviceStatus
Device status of read point
HardwareRevision
Hardware version of the communication module
LastScanData
Most recently scanned transponder of the read point (Scan, ScanStart).
Manufacturer
Manufacturer (always "Siemens AG")
Model
Variant of the communication module
RevisionCounter
Always "-1"
SerialNumber
Serial number of the communication module
SoftwareRevision
Software version of the communication module
Refer to the "OPC Unified Architecture for AutoID" specification for a more detailed
description of the methods/functions.
You can refer to the XML device description file "SimaticIdent.RFxxxx.xml" supplied with
each communication module for the IDs of the nodes described here. An XML device
description file is stored on the communication module and can be downloaded via the WBM
("System > Device description file"). Alternatively, you can also find the node IDs through
browsers by means of a generic OPC UA client through the address area of the server.