Programming via OPC UA
10.3 OPC UA events
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
138
Operating Instructions, 04/2020, C79000-G8976-C512-03
Table 10- 30 Command
Data type
String
Description
Command that was executed during the last transponder access
operation.
Possible values
Depending on the client interface used:
PNIO, PB, EIB
(Ident profile):
•
INVENTORY
•
WRITE-ID
•
KILL-TAG
•
LOCK-TAG-BANK
•
PHYSICAL-READ
•
PHYSICAL-WRITE
•
FORMAT
•
TAG-STATUS
•
GET
•
PUT
•
NEXT
PNIO, PB (FB 45):
•
WRITE
•
READ
•
INIT
•
MDS-STATUS
OPC UA:
•
Scan
•
ReadTag
•
WriteTag
•
KillTag
•
LockTag
•
SetTagPassword
•
Read
•
Write
WBM, XML:
•
readTagIDs
•
writeTagID
•
readTagMemory
•
writeTagMemory
•
killTag
•
lockTagBank
•
getTagStatus
READPOINT:
•
Observed
--
The property "LastAccessResult" is a field of "RfidLastAccessResult" structures. A field entry
or a structure carries the information for a transponder that was accessed by the
"Command". If multiple transponders were accessed by the command, the field has multiple
entries.