Programming Manual
–
T3AWG3K-C Series Arbitrary Waveform Generator
True-Arb Operating Mode
115
Returns
<mode>::= { FIRST|PREVious|NEXT|LAST|ITEM }
Example
SEQuence:ELEM4:PATTERNJUMPTOMode LAST
The sequencer will jump to the last element after the pattern jump
event occurs.
SEQuence:ELEM4:PATTERNJUMPTOMode?
Might return LAST
Table 157: SEQuence:ELEM[n]:PATTERNJUMPTOMode
Command
SEQuence:ELEM[n]:PATTERNJUMPTOEntry
Description
This command sets or returns the target entry index for the “Pattern
Jump To” command for the selected element ‘n’ of the sequencer.
The “Pattern Jump” is a conditional jump that occurs when a
Pat-
tern code is received by the sequencer.
As soon as the sequencer receives this pattern event, it will jump to
the entry selected in this command.
Note
:
this will take effect only when SEQuence:ELEM[n]: PATTERNJUMPTO-
Mode is set to ITEM
Group
Sequence
Syntax
SEQuence:ELEM[n]:JUMPTOEntry
{MINimum|MAXimum|DEFault|<value>}
SEQuence:ELEM[n]:JUMPTOEntry? [{MINimum|MAXimum}]
Related Commands
SEQuence:ELEM[n]:PATTERN
SEQuence:ELEM[n]:PATTERNJUMPTOEntry
AWGControl:DJStrobe
Arguments
•
MINimum: sets the parameter to the minimum value
•
MAXimum: sets the parameter to the maximum value
•
DEFault: sets the parameter to the default value
•
< value >:= <NR1> sets the target entry index
Returns
< value > := <NR1>
Example
SEQuence:ELEM4:PATTERN 123