AD4329A-DLC
Page 42
11.2. Command format
When F-41 is 3, the master device sends a command. Data
will be read, a function will be executed, or data will
be written.
・
When transmitting the following command, corresponding
data will be sent.
RW<CR><LF>
Reading a displayed value
・
When transmitting the following command, the function according the command will be executed and the
command will be echoed back.
MZ<CR><LF>
Set the current display to the zero point.
MT<CR><LF> Execute
tare
CT<CR><LF>
Clear the tare value
MG<CR><LF>
Switch the display to gross value.
MN<CR><LF>
Switch the display to net value.
・
When transmitting
the following command and writing data
is
sent, the data will be updated and the
command and writing data will be echoed back.
PT,+213<CR><LF>
Write a preset tare value. (Command shown at the left will write +213.)
HI,+5000<CR><LF>
Write an upper limit value (Command shown at the left will write +5000.)
LO,-560<CR><LF>
Write a lower limit value (Command shown at the left will write +560.)
・
Error response
I<CR><LF>
Response to an unacceptable command.
?<CR><LF>
The command is incorrect.
・
Communication example
RW<CR><LF>
ST,G<SP>,+01234.5kg<CR><L
AD4329A-DLC
MT<CR><LF>
Master
MT<CR><LF>
PT,+213<CR><LF>
PT,213<CR><LF>
Taring execution
Up213 as preset tare value.
Response for the displayed value