372
Agilent X-Series Signal Generators SCPI Command Reference
Digital Signal Interface Module Commands
Digital Subsystem—Option 003 and 004 ([:SOURce])
Example
:DIG:DATA:OUTP:TYPE PFS
The preceding example sets the data type to pre- filtered I and Q data.
*RST
SAMP
Key Entry
Data Type
:DIGital:DIAGnostic:LOOPback
Supported
N5172B/82B with option 003 or 004 or both
:DIGital:DIAGnostic:LOOPback? DIGBus|CABLe|N5102A|DEVice
This command selects and executes a loop back test that validates the integrity of digital data.
DIGBus
This choice selects a loop back test on the Digital Bus connector at the signal
generator side.
CABLe
This choice selects a loop back test using the Digital Bus Loop Back Fixture test
board.
N5102A
This choice selects a loop back test for the N5102A module.
DEVice
This choice selects a loop back test using the LOOP BACK TEST SINGLE ENDED
IO DUAL 40 PIN board.
Example
:DIG:DIAG:LOOP? DEV
The preceding example runs the diagnostic test on the Single Ended IO Dual 40 Pin
device and
returns a pass or fail condition.
*RST
Device Intfc
Key Entry
Loop Back Test Type
:DIGital:LOGic[:TYPE]
Supported
N5172B/82B with option 003 or 004 or both
:DIGital:LOGic[:TYPE] LVDS|LVTT1|CMOS15|CMOS18|CMOS25|CMOS33|SSI
:DIGital:LOGic[:TYPE]?
This command selects the logic data type used by the device being tested.
LVDS
This choice selects low voltage differential signaling as the logic data type.
LVTT1
This choice selects a low voltage TTL signal as the logic data type.
CMOS15
This choice selects a 1.5 volt CMOS signal as the logic data type.
CMOS18
This choice selects a 1.8 volt CMOS signal as the logic data type.
CMOS25
This choice selects a 2.5 volt CMOS signal as the logic data type.
CMOS33
This choice selects a 3.3 volt CMOS signal as the logic data type.
SSI
This key sets the logic type of the device interface to SSI (simple serial interface).