Rev. B
6-56
HMXMC001013
31-Mar-06
6.16 ERROR
LOG
The MAXPRO-Net
system uses the Error Log database to save details of macro errors,
system fault information, and changes in operational status. Click on the Error Log tab to
display the contents of the error log database.
Each entry in the file includes the date and time information, as well as details of the
change or error that caused the entry. Macro errors are labeled with a macro error
number. For details of macro error numbers, please refer to the table below.
Macro Error Definition Table
01 Format error in extended command
02 Format error in conditional command
03 Unknown command in expression evaluation
04 Unknown command in update expression
05 Numeric variable range error
06 Scan sequence range error
07 External alarm range error
08 Auxiliary control output range error
09 Invalid numeric evaluation error
10 Macro timer range error
11 Macro timer command error
12 Macro timer period error
13 System macro range error
14 Unknown video output channel
15 Unknown video input source
16 Invalid external alarm control logic
17 Invalid auxiliary output control logic
18 Invalid camera disable logic
19 Invalid PTZ speed
20 Unknown system constant error
21 Unknown text message command error
22 Invalid operator sign used with commands
23 Invalid keyboard identification number
24 Invalid alarm stack entry i.e.: not an alarm macro
25 Invalid alarm display group (1 50) only
26 Macro string exceeds 255 characters
27 Conditional statement missing closed brackets
28 Invalid real time clock time or date definition
29 Invalid video source command
30 String variable command format error
31 String variable range error
32 Unknown evaluate command for string
33 Too many nested do-while loops
34 Format error in do-while loop
35 Maximum loop cycles has been exceeded