© 2022 HyQuest Solutions
77
Configuration
Endianness:
Little
Start Register:
1
5. In the
REGISTERS
section select the
FLOAT
data type and click the
ADD
button. This will add Float datatype to the
Registers List. In this example this represents the wind speed. If the type is incorrect then click the tick box next to the
incorrect datatype in the list, choose the correct type and click the Change button.
6. In the
REGISTERS
section select the
U_INT16
data type and click the
ADD
button. This will add U_INT16 datatype to the
Registers List. In this example this represents the wind direction.
7. In the
REGISTERS
section select the
FLOAT
data type and click the
ADD
button. This will add Float datatype to the
Registers List. In this example this represents the Air Temperature. The Resisters list should look like this:
8. Click the Send Config button to commit this to the iRIS.
9. Click the Retrieve Config button to obtain the dynamically created indices.
10. Navigate to the Sensors section of the configuration tree and click the + Add Sensor branch.
11. In the newly created sensor enter the following:
Name:
Wind Speed
Source:
Modbus Device
Modbus Device:
<Name given in step 3>