Index
(hex)
Name
Description
Data
type
Flags
Default
1C33:0A Sync0 Cycle Time
RW
0x00000000
1C33:0B
SM-Event Missed
Number of missed SM events
in OPERATIONAL (DC
mode only)
RO
0x0000
1C33:0C
Cycle Time Too Small
Cycle was not completed in
time or the next cycle began
too early
RO
0x0000
1C33:20
Sync Error
The synchronization was not
correct in the last cycle
(outputs were output too late;
DC mode only)
RO
FALSE
8.5 Input Data
"n" represents the channel number (0 to 1)
Index 0x60n0 ENC Inputs Ch.n
Index
(hex)
Name
Description
Data type
Flags
Default
60n0:0
Encoder input status Ch.n
Encoder status inputs
UINT8
RO
0x12
60n0:01
Set counter done
Assigning the counter
a new value has
completed. Indicates
whether the "Set
counter" (70n0:04)
action was successful
BOOLEAN
RO
60n0:02
Reset index latch value done Indicates that the
index latch value has
been set to zero
BOOLEAN
RO
60n0:03
Signal of input A
Signal of input A
BOOLEAN
RO
60n0:04
Signal of input B
Signal of input B
BOOLEAN
RO
60n0:05
Signal of input C
Signal of input C
BOOLEAN
RO
60n0:06
Enable extern latch done
Indicates whether the
external latch has been
enabled
BOOLEAN
RO
60n0:07
Reset extern latch value
done
Indicates whether the
external latch counter
has been reset
BOOLEAN
RO
60n0:08
Enable compare done
Indicates whether the
position compare
function has been
enabled
BOOLEAN
RO
60n0:0F
Sync error
The Sync error bit is
only required for DC
BOOLEAN
RO
ICP DAS
Page
ECAT-2092T User Manual
Version 1.0
63
Summary of Contents for ECAT-2092T
Page 3: ...Revision Revision Date Description Author 1 18 02 2019 Initial version M K...
Page 50: ...Table 23 Resetting latch register procedure ICP DAS Page ECAT 2092T User Manual Version 1 0 50...
Page 55: ...Step 5 Set the ECAT 2092T back into OP mode ICP DAS Page ECAT 2092T User Manual Version 1 0 55...
Page 70: ......