# cd /opt/MegaRAID/MegaCli
# ./MegaCli64 -Pdlist -aAll |grep "Slot \|Firmware"
Slot Number: 0
Firmware state:Online, Spun Up
Device Firmware Level: 0868
Slot Number:1
Firmware state:Online, Spun Up
Device Firmware Level: 0868
Slot Number:2
Firmware state:Online, Spun Up
Device Firmware Level: A2A8
Slot Number:3
...
7.
Examine the output of the following command:
/opt/MegaRAID/MegaCli/MegaCli64 -LdInfo -LAll -aAll
8.
(Oracle Exadata Database Machine based on Sun Fire X4170 Oracle Database
Servers only) Check that the ILOM is configured for the proper fan cooling on each
database server using the following command:
# ipmitool sunoem cli "show /SP/policy"
•
If the policy is present and enabled, then no additional steps are needed.
•
If the policy is present and disabled, then enable the policy using the following
command:
# ipmitool sunoem cli "set /SP/policy FLASH_ACCELERATOR_CARD_ \
INSTALLED=enabled"
The command must be entered as a single line.
9.
Log out of the system using the following command:
# logout
10.
Return to the User Interface on the KVM switch by pressing the Ctrl key on the left
to return to the KVM switch, and select Disconnect Session, if using the KVM
switch to access the server.
11.
Select Target Devices from Unit View, and proceed to the next database server, if
using the KVM switch to access the server.
12.
Verify that NTP servers are configured the same for all servers using the following
command. The command is run on each database server individually.
ntpq -p
5.6 Performing Additional Checks and Configuration
The following procedure describes additional checks and configuration steps for
Oracle Exadata Rack:
1.
(Oracle Exadata Database Machine only) Log in to the first database server as the
root
user.
2.
Change to the
firstconf
directory using the following command:
# cd /opt/oracle.SupportTools/firstconf
3.
Create a group file with the list of IP addresses to use in the dcli utility commands,
if needed
Chapter 5
Performing Additional Checks and Configuration
5-59