Commands listed in alphabetical order
BUS:B<x>:MIL1553B:RESPonsetime:MAXimum
This command sets or queries the maximum response time to a valid command
issued for the speci
fi
ed MIL-STD-1553 bus. The bus is speci
fi
ed by x.
Conditions
Requires option SR-AERO.
Group
Bus
Syntax
BUS:B<x>:MIL1553B:RESPonsetime:MAXimum
<NR3>
BUS:B<x>:MIL1553B:RESPonsetime:MAXimum?
Related Commands
BUS:B<x>:MIL1553B:RESPonsetime:MINimum
Arguments
<NR3>
is a
fl
oating point number that speci
fi
es the maximum response time, in
seconds.
Examples
BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM 15.0E-6
speci
fi
es the
maximum response time to a valid command received to be 15.0 microseconds.
BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM?
might return
:BUS:B1:MIL1553B:RESPONSETIME:MAXIMUM 12.000E-6
, indicating a
maximum response time of 12 microseconds.
BUS:B<x>:MIL1553B:RESPonsetime:MINimum
This command sets or queries the minimum response time to a valid command
issued for the speci
fi
ed MIL-STD-1553 bus. The bus is speci
fi
ed by x.
Conditions
Requires option SR-AERO.
Group
Bus
Syntax
BUS:B<x>:MIL1553B:RESPonsetime:MINimum
<NR3>
BUS:B<x>:MIL1553B:RESPonsetime:MINimum?
Related Commands
BUS:B<x>:MIL1553B:RESPonsetime:MAXimum
MSO54, MSO56, MSO58, MSO58LP Programmer
2-157
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...