Commands listed in alphabetical order
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:LIN:CONDition
{SYNCfield|IDentifier|DATa|IDANDDATA|WAKEup|SLEEP|ERRor}
TRIGger:{A|B}:BUS:B<x>:LIN:CONDition?
Arguments
SYNCfield
sets the LIN trigger condition to sync
fi
eld.
IDentifier
sets the LIN trigger condition to identi
fi
er.
DATa
sets the LIN trigger condition to data.
IDANDDATA
sets the LIN trigger condition to id and data.
WAKEup
sets the LIN trigger condition to wake up.
SLEEP
sets the LIN trigger condition to sleep.
ERRor
sets the LIN trigger condition to error.
Examples
TRIGGER:A:BUS:B1:LIN:CONDITION ERROR
sets the LIN trigger condition
to error.
TRIGGER:A:BUS:B1:LIN:CONDITION?
might return
TRIGGER:A:BUS:B1:LIN:CONDITION SYNCFIELD
indicating the LIN trigger
condition is sync
fi
eld.
TRIGger:{A|B}:BUS:B<x>:LIN:DATa:HIVALue
This command speci
fi
es the high data value string used for a LIN bus trigger
when the trigger condition is DATA or IDANDDATA and the data quali
fi
er is
INRANGE or OUTRANGE. The bus number is speci
fi
ed by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:LIN:DATa:HIVALue <QString>
TRIGger:{A|B}:BUS:B<x>:LIN:DATa:HIVALue?
2-810
MSO54, MSO56, MSO58, MSO58LP Programmer
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...