Command groups
Measurement command group
Use the commands in the Measurement Command Group to control the automated
measurement system.
Measurement commands can set and query measurement parameters. You can
assign parameters, such as waveform sources and reference levels, differently
for each measurement.
Clock recovery, edge,
fi
lter, gating, population and range measurement commands
can be either global or per-measurement.
Global clock recovery commands are of the form
:MEASUrement:CLOCKRecovery:XXXX
Global edge commands are of the form
:MEASUrement:XXXX
Global
fi
lter commands are of the form
:MEASUrement:FILTers:XXXX
Global gating commands are of the form
:MEASUrement:GATing:XXXX
Global population commands are of the form
:MEASUrement:POPUlation:XXXX
Global range commands are of the form
:MEASUrement:MEASRange:XXXX
Reference levels for measurements can be global, per-measurement
or per-source. The default is global. Per-measurement settings are
used when local reference levels are enabled for the measurement with
the command
:MEASUrement:MEAS?:GLOBalref 0
. Per-source
settings are used when per-source settings are enabled with the
command
:MEASUrement:REFLevels:TYPE PerSource
and
per-source settings are selected for the measurement with the command
:MEASUrement:MEAS?:GLOBalref 0
.
Global reference level commands are of the form
:MEASUrement:REFLevels:XXXX
Per-source reference level commands are of the form
:MEASUrement:CH1:REFLevels:XXXX
:MEASUrement:MATH1:REFLevels:XXXX
Table 2-31: Measurement commands
Command
Description
This command returns all measurement parameters.
This command adds a measurement.
Adds the speci
fi
ed measurement.
This command sets or queries the annotation state for measurements.
Performs an analysis jitter autoset.
MEASUrement:CH<x>:REFLevels:ABSolute:
FALLHigh
This command sets or queries the value used as the high reference level of the falling
edge when the source ref level method is set to absolute.
MEASUrement:CH<x>:REFLevels:ABSolute:
FALLLow
This command sets or queries the value used as the low reference level of the falling
edge when the source ref level method is set to absolute.
MSO54, MSO56, MSO58, MSO58LP Programmer
2-39
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...