background image

 

 11 

LOCATIONS 078-085: PROGRAMMING THE ZONE TYPES

 

 
Locations 078 through 085 contain a number identifying the characteristics of each of the 8 zones. Location 078 
corresponds  to  zone  1  and  location  085  corresponds  to  zone  8.  Each  zone  will  factory  default  according  to  the 
programming worksheet. To program zone characteristics other than the default values, program a number from "1" to 
"9" based on the zone types available in the chart on the following page. 
 

 

  DATA 

 
 

AVAILABLE ZONE TYPES 

 

 

"1" 

 

DAY ZONE

 - When armed, a trip produces an instant alarm. When disarmed, a trip activates the keypad 

sounder. 

 
 

"2" 

 

24 HOUR

 - A trip on a 24 Hour zone produces an instant alarm when armed or disarmed. 

 
 

"3" 

 

ENTRY/EXIT

 - A trip will start entry delay. The lack of a trip during exit delay will enable the Automatic 

Bypass or Instant mode if so programmed. 

 
 

"4" 

 

INTERIOR DELAY

 - A trip on Interior Delay zone will initiate an entry delay. It will be ignored during exit 

delay and when disarmed . 

 
 

"5" 

 

INTERIOR FOLLOWER

 - Interior zone that follows the delay zones. It is instant during non-delay times. It 

can be bypassed before arming, or by allowing it to automatically be bypassed in the Automatic 
Bypass/Instant mode if so programmed. 

 
 

"6" 

 

INSTANT

 - Produces an instant alarm if tripped when armed. Ignored when disarmed. 

 
 

"7" 

 

24 HOUR SILENT

 -  A trip on a 24 hour silent zone will communicate to the central station when the 

Ranger 8980 is armed or disarmed.  

 
 

"8" 

 

FIRE

 (PRIORITY WHEN AHJ HAS NOT APPROVED) - A short on a FIRE zone (non-bypassable) will 

communicate to the central station when the Ranger 8980 is armed or disarmed. An open will create a 
Trouble condition. Keypad LED will be steady for FIRE, and flashing for Trouble. 

 
 

"9" 

 

SECONDARY DELAY

 - A secondary delay zone works like an entry/exit delay zone but has its own 

independent delay time (see locations 178-179).  

 
 

NOTE:  WHEN PROGRAMMING THE FOLLOWING COMMUNICATOR CODES,  

 

A "10" MUST BE PROGRAMMED IN ORDER TO REPORT A ZERO (0). 

 

 

LOCATION 086-087: PROGRAMMING THE RANGER 8980 FOR DURESS CODE CAPABILITY

 

 
The Ranger 8980 has the ability to report a duress code when the system is armed or disarmed with user code number 
7 and a duress communicator code is programmed in locations 086-087. If both locations are "0", the duress capability 
is disabled and user code number 7 can only be used as a standard arm/disarm code. Location 086 contains the 
standard digit, and location 087 contains the extended digit. When using 4+2 format, the number programmed in 
location 086 is sent as the "ones" digit. The "tens" digit is programmed in location 087. 

NOTE: ENABLING THE 

MAINTENANCE CODE FEATURE IN LOCATION 167 WILL AUTOMATICALLY DISABLE THE DURESS FEATURE.

 

      

LOCATION 088-089: PROGRAMMING FOR AUXILIARY 1, [1] & [3] DOUBLE KEYPRESS 

 

 
The Ranger 8980 has the ability to report an Auxiliary 1 code and activate the Priority siren each time the [1] and [3] 
keys are pressed simultaneously on the keypad. The desired reporting code is programmed in locations 088-089. If 
both locations are "0", the Auxiliary 1 double keypress is disabled. Location 088 contains the standard digit, and 
location 089 contains the extended digit. When using a 4+2 format, the number programmed in location 088 is sent as 
the "ones" digit. The "tens" digit is programmed in location 089. If activated, the siren can be silenced by entering any 
arm/disarm code.  
 

Summary of Contents for Ranger 8980

Page 1: ...PTION 4 HOW TO PROGRAM THE RANGER 8980 6 KEYPAD PROGRAMMING EXAMPLES 7 PROGRAMMING PHONE NUMBERS FORMATS 8 9 COMMUNICATOR FORMAT SELECTION GUIDE 9 OPTIONAL PROGRAMMING INSTRUCTIONS 10 22 AVAILABLE ZON...

Page 2: ...he Ranger 8980 functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Stand...

Page 3: ...3 PARTS DIAGRAM...

Page 4: ......

Page 5: ...e Ring red 20 R1 House Telephone Ring gray 21 22 Siren driver output to speaker s speaker rating should be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in...

Page 6: ...icating the data in that location to be 6 If no LED s are illuminated the location contains a 0 To advance from location 000 through 180 press the key To go to a specific location press the location n...

Page 7: ...8...

Page 8: ...1800HZ 2300HZ Fast with Parity and Hex Capability requires a 9 in this location If you need another format choose from those listed on the format table located on page 13 and program the data in loca...

Page 9: ...Z HANDSHAKE DOUBLE ROUND PARITY 20 PPS 5 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 6 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 1400HZ HA...

Page 10: ...GITS With the Ranger 8980 disarmed the Go To Program access code can be used to enter the program mode To disable the Go To Program access code program a 15 in location 028 The factory default setting...

Page 11: ...8980 is armed or disarmed An open will create a Trouble condition Keypad LED will be steady for FIRE and flashing for Trouble 9 SECONDARY DELAY A secondary delay zone works like an entry exit delay zo...

Page 12: ...rammed in location 094 is sent as the ones digit The tens digit is programmed in location 095 LOCATION 096 097 PROGRAMMING TO REPORT DOWNLOADING COMPLETE Locations 096 097 contain the communicator rep...

Page 13: ...ZONE 4 Locations 110 111 contain the communicator code to be reported each time zone 4 creates an alarm Location 110 contains the standard digit and location 111 contains the extended digit When usin...

Page 14: ...a bypass immediately When a bypass is removed a restore will be reported if Restore is enabled in location 126 LOCATION 126 PROGRAMMING THE COMMUNICATOR CODE FOR RESTORAL Location 126 contains the co...

Page 15: ...he following procedure First remove the jumper marked voltage siren on the PC board Next program a 1 in location 132 Finally replace the jumper in the voltage position Terminals 21 22 will now output...

Page 16: ...d a 1 is programmed in location 141 all reports will be double line extended If location 141 contains a 0 only non alarm reports will be extended restore cancel opening closing bypass and trouble With...

Page 17: ...ORITY SIREN RECYCLED OUTPUT 4 ARMED WITH BYPASS LATCHED OUTPUT 5 AC POWER LATCHED OUTPUT 6 LOW BATTERY LATCHED OUTPUT 7 ALARM MEMORY LATCHED OUTPUT 8 ENTRY LATCHED OUTPUT 9 EXIT MOMENTARY OUTPUT LOCAT...

Page 18: ...55 contains the current year ones digit If the current year is 1994 this location should contain a 4 which is the ones digit of the current year If the current year is 1995 this location should contai...

Page 19: ...t of the minutes after the hour that the autotest is desired The time is entered in 24 hour time If the desired autotest time is 5 25 PM the 24 hour time is 17 25 so this location should contain a 2 w...

Page 20: ...ime user number 7 arms the control The desired closing code should be programmed in this location This feature can be used in conjunction with the rotating maintenance code to give a closing report ea...

Page 21: ...ST TO REPORT TO THE SECONDARY PHONE NUMBER The 8980 is capable sending certain reports to the secondary telephone number This feature known as split reporting can be used to send alarm reports to one...

Page 22: ...9 AC FAIL OPEN CLOSE A 10 AC FAIL OPEN CLOSE MAINT CODE OPEN CLOSE B 11 AC FAIL LOW BATTERY C 12 AC FAIL LOW BATTERY MAINT CODE OPEN CLOSE D 13 AC FAIL LOW BATTERY OPEN CLOSE E 14 AC FAIL LOW BATTERY...

Page 23: ...umber programmed in location 210 maximum 3 The control panel will detect these rings and start a 45 second timer If a call comes in during that 45 second time frame the control panel will answer on th...

Page 24: ...SECONDARY ACCOUNT CODE 0 DISABLED 074 9 SECONDARY FORMAT 0 DISABLED CONTROL COMMUNICATOR FEATURES LOCATION PAGE DESCRIPTION DATA DEFAULT 075 10 ENTRY DELAY TIME 10 SECOND INCREMENTS 3 30 SECONDS 076...

Page 25: ...ANT ARMING 0 DISABLED 132 15 SIREN DRIVER OR VOLTAGE OUTPUT 0 SIREN DRIVER 133 15 LED EXTINGUISH FEATURE 0 DISABLED 134 15 NUMBER OF DIAL ATTEMPTS 8 EIGHT ATTEMPTS 135 15 POWER UP CONDITION 0 LAST CON...

Page 26: ...DIGIT 4 0 172 20 USER 7 MAINTENANCE CODE OPENING REPORT 0 DISABLED 173 20 USER 7 MAINTENANCE CODE CLOSING REPORT 0 DISABLED 174 20 PROGRAM ZONES 3 THRU 6 FOR NORMALLY CLOSED OPERATION 0 SUPERVISED 17...

Page 27: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Page 28: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...