LOCATION 103: PROGRAMMING TO REPORT OPENINGS
The Ranger 8980 has the ability to report an opening code each time the control is disarmed. The desired opening
code is programmed in location 103. If this location contains a "0", openings will not be reported. When using 4+2
format, the number programmed in this location is sent as the"tens" digit. The "ones" digit is automatically the man
number. When using the remote arming input, the man number is 1.
LOCATION 104-105: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 1
Locations 104-105 contain the communicator code to be reported each time zone 1 creates an alarm. Location 104
contains the standard digit, and location 105 contains the extended digit. When using 4+2 format, the number
programmed in location 104 is sent as the "ones" digit. The "tens" digit is programmed in location 105.
LOCATION 106-107: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 2
Locations 106-107 contain the communicator code to be reported each time zone 2 creates an alarm. Location 106
contains the standard digit, and location 107 contains the extended digit. When using 4+2 format, the number
programmed in location 106 is sent as the "ones" digit. The "tens" digit is programmed in location 107.
LOCATION 108-109: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 3
Locations 108-109 contain the communicator code to be reported each time zone 3 creates an alarm. Location 108
contains the standard digit, and location 109 contains the extended digit. When using 4+2 format, the number
programmed in location 108 is sent as the "ones" digit. The "tens" digit is programmed in location 109.
LOCATION 110-111: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 4
Locations 110-111 contain the communicator code to be reported each time zone 4 creates an alarm. Location 110
contains the standard digit, and location 111 contains the extended digit. When using 4+2 format, the number
programmed in location 110 is sent as the "ones" digit. The "tens" digit is programmed in location 111.
LOCATION 112-113: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 5
Locations 112-113 contain the communicator code to be reported each time zone 5 creates an alarm. Location 112
contains the standard digit, and location 113 contains the extended digit. When using 4+2 format, the number
programmed in location 112 is sent as the "ones" digit. The "tens" digit is programmed in location 113.
LOCATION 114-115: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 6
Locations 114-115 contain the communicator code to be reported each time zone 6 creates an alarm. Location 114
contains the standard digit, and location 115 contains the extended digit. When using 4+2 format, the number
programmed in location 114 is sent as the "ones" digit. The "tens" digit is programmed in location 115.
LOCATION 116-117: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 7
Locations 116-117 contain the communicator code to be reported each time zone 7 creates an alarm. Location 116
contains the standard digit, and location 117 contains the extended digit. When using 4+2 format, the number
programmed in location 116 is sent as the "ones" digit. The "tens" digit is programmed in location 117.
LOCATION 118-119: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 8
Locations 118-119 contain the communicator code to be reported each time zone 8 creates an alarm. Location 118
contains the standard digit, and location 119 contains the extended digit. When using 4+2 format, the number
programmed in location 118 is sent as the "ones" digit. The "tens" digit is programmed in location 119.