Command
Description
STATus?
Returns the Status register bits as a decimal
number. What the bits represents is listed in
Table 2.
STATus:OPERation?
Returns the Status:Operations register bits as a
decimal number. What the bits represents is listed
in Table 3.
STATus:OPERation:REG1?
Returns the Status:operations:REG1 register bits
as a decimal number. These are the
warning/interlock bit, but the exact mapping is
Listed in Table 4.
STATus:OPERation:REG2?
Returns the Status:operations:REG2 register bits
as a decimal number. These are the
warning/interlock bit, the exact mapping is listed
in Table 5.
STATus:OPERation:REG3?
Returns the Status:operations:REG3 register bits
as a decimal number. These are the
warning/interlock bit, the exact mapping is listed
in Table 6.
STATus:OPERation:REG4?
Returns the Status:operations:REG4 register bits
as a decimal number. These are the
warning/interlock bit from the digiloop card, the
exact mapping is listed in Table 7.
[:SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]
{<level (A)>
Sets the current
[:SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]
?
Returns the set current
[:SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
{<level (V)>
Sets the voltage
[:SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
?
Returns the set voltage
OUTPut:RELay[:STATe] {0|1|2|STB|ON|OFF}
Sets the state of the system, on/off/standby. 0 =
STB, 1 = ON, 2 = OFF. The system must be in
STB before it can be set in ON state.
OUTPut:RELay[:STATe]?
Returns the state of the system 0 = STB, 1 = ON,
2 = OFF, 3 = ERROR.
MEASure[:SCALar]:VOLTage[:DC]?
Returns the read voltage
MEASure[:SCALar]:CURRent[:DC]?
Returns the read current
SYSTem:DATE yyyy, mm, dd
Sets the date. Both e.g. “9” and “09” will work for
setting moth and day.