User Manual DEV 1953
Copyright DEV Systemtechnik GmbH 2015-2017
131
5.9.4.4.4.4
.surveillance.errorTable.errorEntry.errorDateTime
OID:
.1.3.6.1.4.1.21035.41.3.4.1.4
.x
Syntax:
INTEGER32
Access:
read-only
Description:
The last occurrence of the event
(Unix time stamp, seconds since 01-Jan-1970 00:00:00 UTC)
Example:
"
1506018712
" ≡ 21-Sep-2017 18:31:52 CEST
5.9.4.4.4.5
.surveillance.errorTable.errorEntry.errorPending
OID:
.1.3.6.1.4.1.21035.41.3.4.1.5
.x
Syntax:
INTEGER {pending (1), gone (2)}
Access:
read-only
Description:
The last occurrence of the event is
"
1
" still pending, or
"
2
" not pending anymore, i.e. gone.
5.9.4.4.4.6
.surveillance.errorTable.errorEntry.errorAcknowledge
OID:
.1.3.6.1.4.1.21035.41.3.4.1.6
.x
Syntax:
INTEGER {notAcknowledged (1), acknowledged (2)}
Access:
read-only
Description:
The last occurrence of the event is
"
1
" not acknowledged, or
"
2
" acknowledged.
5.9.4.4.5
.surveillance.numberOfPowerLines
OID:
.1.3.6.1.4.1.21035.41.3.5
.0
Syntax:
INTEGER32
Access:
read-only
Description:
The number of power lines. This type of device supports
monitoring for the two power lines, thus "
2
" is returned.
Note:
This value is used to determine the maximum index of the following table:
5.9.4.4.6
.surveillance.powerLineTable
With the .powerLineTable the status of each power line can be checked.
5.9.4.4.6.1
.surveillance.powerLineTable.powerLineEntry.powerLineIndex
OID:
.1.3.6.1.4.1.21035.41.3.6.1.1
.x
Syntax:
INTEGER32 (1..3)
Access:
not-accessible
Description:
A unique value for each table entry ranging between "
1
" and the
number of entries (defined by .numberOfPowerLines, please refer
to chapter 5.9.4.4.5 ).
5.9.4.4.6.2
.surveillance.powerLineTable.powerLineEntry.powerLineStatus
OID:
.1.3.6.1.4.1.21035.41.3.6.1.2
.x
Syntax:
INTEGER {ok (1), notok (2), notapplicable (3)}
Access:
read-only