Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menu 10
Unidrive SP Advanced User Guide
179
Issue Number: 10 www.controltechniques.com
These flags are set by the speed detector in menu 3.
See Pr
Indicates that the modulus of the active current is greater or equal to the rated active current as defined in menu 4.
Indicates that the current limits are active.
Open-loop, Closed-loop vector, Servo
Indicates that power is being transferred from the motor to the drive.
Regen
Indicates that power is being transferred from the drive to the supply.
Indicates that the Braking IGBT is active. If the IGBT becomes active this parameter is held on for at least 0.5s so that it can be seen on the display.
This parameter is set when the braking IGBT is active and the braking energy accumulator is greater than 75%. This parameter is held on for at least
0.5s so that it can be seen on the display.
10.07
Above set speed
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background write
10.08
Load reached
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background write
10.09
Drive output is at current limit
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
4ms write
10.10
Regenerating
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
4ms write
10.11
Braking IGBT active
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
4ms write
10.12
Braking resistor alarm
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Update rate
Background write
Summary of Contents for unidrive sp