FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
146
of
170
15 A
PPENDIX
1:
D
ATA
S
TRUCTURE
P
ROFIBUS
,
P
ROFINET
,
E
THER
NET/IP,
E
THER
CAT,
CC-L
INK
,
P
OWERLINK
,
CC-L
INK
IE
FT-112(D) Panel Output to PLC Input
Bitwise of a Dword:
Dword
(Only
read)
B31 B30 B29 B28 B27 B26 B25 B24 B23 B22 B21 B20 B19 B18 B17 B16
B15 B14 B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
1st
Dword
(INPUT)
(RWr0,
RWr1)
By default, Actual weight value is represented.
To represent other weight or calibration status, refer to next Dword.
2nd
Dword
(INPUT)
(RWr2,
RWr3)
Out
5
Out
4
Out
3
Out
2
Out
1
In
4
In
3
In
2
In
1
Error codes of FT-
112(D) Panel
Unit
P.Tare
Centre
of zero
Gross
Net
SD
Read command response
Cmd
Flg
FT-112(D) Panel Output to PLC Input 2
nd
Dword
Bit Number 2
nd
Dword Description
B31… B24
Digital
Outputs
Output bit status (Active = 1)
B23… B16
Digital Inputs Input bit status (Active = 1)
B15… B12
Error Codes
of FT-112(D)
Panel
Bin
Dec
Descriptions
0000
0
No error found
0001
1
ADC out
0010
2
ADC over
0011
3
ADC under
0100
4
System Error
0101
5
In programming mode
0110
6
Low/High Voltage Error
0111
7
Tilt Switch is active
B11
Unit
0
First unit
1
Second unit
B10
Not used
B9
Preset Tare
0
Preset tare is passive
1
Preset tare is active
B8
Centre of
zero
0
Weight is out of zero range
1
Weight is in zero range
B7
Indication
0
Gross
1
Net
B6
Stability
Detection
0
Stable
1
Unstable