Master position settings and values.
Master position
87
- / int32
Displays the value received from the source selected
by
.
Master position
reference input
87.1
This parameter is read-only.
- / -
Master position reference.
-2147483648...2147483647
increments
- / int32
Displays the ungeared and unfiltered master position
reference.
Master position
reference ungeared
87.2
This parameter is read-only.
- / -
Ungeared, unfiltered master position reference.
-2147483648...2147483647
increments
- / real32
Displays the geared and filtered master position
reference.
Master position
reference geared
87.3
This is the product of
and the master axis feed
constant configurations. The range is defined by the
master axis modulo configuration settings.
This parameter is read-only.
1000 = 1 units / 1000
= 1 units
Geared, filtered master position reference.
-2000000.000 ...
2000000.000 units
- / real32
Displays the master axis velocity in engineering units
per second.
Master velocity
reference
87.4
This parameter is read-only.
1000 = 1 units/s /
1000 = 1 units/s
Master axis velocity.
-2000000.000 ...
2000000.000
units/s
- / int32
Displays the difference between the unfiltered master
position reference and the compensated, filtered values
in increments.
Master reference
error raw
87.5
This parameter is read-only.
- / -
Master reference error.
-2147483648...2147483647
increments
- / real32
Displays the difference between the unfiltered master
position reference and the compensated, filtered values
in engineering units.
Master reference
error in units
87.6
This parameter is read-only.
1000 = 1 units / 1000
= 1 units
Master reference error.
-2000000.000 ...
2000000.000 units
- / real32
Displays the actual velocity of the virtual master in
engineering units per second.
Virtual master actual
velocity
87.7
This parameter is read-only.
1000 = 1 units/s /
1000 = 1 units/s
Actual velocity of virtual master.
-2000000.000 ...
2000000.000
units/s
- / int32
Displays the actual position of the virtual master in
increments. The resolution of the virtual master is
defined by
87.10 Master increments per revolution
Virtual master actual
position raw
87.8
This parameter is read-only.
472 Parameters
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...