5
TRIGger
:TIMer <seconds>|MIN|MAX
:TIMer? [MIN|MAX]
This command sets the channel-to-channel interval in the trigger layer
(the
ARM:TIMer
command sets the sweep-to-sweep interval in the
trigger layer). This timer is valid only if the
TIMer
is set using the
TRIGger:SOURce
command.
You can set seconds to any value between 0.000 (
MIN
) and 99999.999
(
MAX
) in increments of 0.001 seconds. When power is applied, the value is
set to 0 (
MIN
).
The
TRIGger:TIMer?
query returns the channel-to-channel interval in
seconds. The returned number is a value between 0 and 99999.999
(seconds). The optional parameters
MIN
and
MAX
allow you to query the
module for these values instead of looking them up in the command
reference.
MIN
returns “0” and
MAX
returns “99999”.
[ROUTe:]
[CHANnel:]DELay <seconds>,<channel_list>|ALL
[CHANnel:]DELay? <channel_list>
This command specifies a delay time (from 0 to 99999.999 seconds, with
1 ms resolution) between when a channel in the scan list is closed and
the next operation begins (and, if configured, a trigger out pulse is sent).
The delay time can be set individually for each channel in the scan list,
or one delay can be set for all channels in the scan list. Note that, even if
the trigger source is set to IMMediate, the scan list will not advance until
the delay time is met. Following power on or a reset (
*RST
) command,
the delay time is set to “0”.
The channel_list can be:
•
a single channel, use
DEL (@snn)
;
•
multiple channels, use
DEL (@snn,snn...)
;
•
sequential channels, use
DEL (@snn:snn)
;
•
groups of sequential channels, use
DEL (@snn:snn,snn:snn)
;
•
or any combination of the above.
The
ROUTe:CHANnel:DELay?
query returns the delay time of each
channel included in the channel_list. A comma-delineated set of values is
returned. The values are in same order as in the channel_list and in the
form of (snn,snn,mm,...), where snn is the channel number and mm is a
stored channel setup.
Summary of Contents for Agilent 3499A
Page 13: ...1 1 Quick Start ...
Page 27: ...2 2 Front Panel Operation ...
Page 55: ...3 3 System Overview ...
Page 77: ...4 4 Features and Functions ...
Page 113: ...5 5 Remote Interface Reference ...
Page 164: ...164 5 ...
Page 165: ...6 6 Error Messages ...
Page 173: ...7 7 Plug in Modules ...
Page 256: ...256 Chapter 7 Plug in Modules 44475A Breadboard Module 7 ...
Page 261: ...261 Chapter 7 Plug in Modules 44476B Microwave Switch Module 4 7 The 44476B is shown below ...
Page 286: ...286 Chapter 7 Plug in Modules Terminals and Connections Information 7 ...
Page 288: ...288 7 ...
Page 289: ...8 8 Application Programs ...
Page 299: ...9 9 Specifications ...
Page 343: ...343 Chapter 9 Specifications 44475A Breadboard Module 4 9 ...