X90 mobile modules
X90 mobile system User's manual V 1.20 - Translation of the original manual
301
5.5.1.7 Register description
5.5.1.7.1 System requirements
The following minimum versions are recommended to generally be able to use all functions:
•
Automation Studio 4.3
•
Automation Runtime 4.3
5.5.1.7.2 Overview of registers
Read
Write
Register
Name
Data type
Cyclic
Acyclic
Cyclic
Acyclic
Communication - Digital inputs
DigitalInputPacked01
UINT
DigitalInput01
Bit 0
...
...
2
DigitalInput10
Bit 9
●
Communication - Counter
6 + (N-1) * 4
Event/PeriodCounterN (index N = 01 to 10)
UINT
●
Communication - Reset counter
ResetCounterPacked01
UINT
ResetCounter01
Bit 0
...
...
2
ResetCounter10
Bit 10
●
Configuration - Filter time of digital inputs
1025 + (N-1) * 2
cfgDigitalFilterN (index N = 01 to 10)
USINT
●
Configuration - Pin configuration
1045 + (N-1) * 2
cfgPinModeN (index N = 01 to 10)
USINT
●
Configuration - Counter configuration
1066 + (N-1) * 4
cfgCounterModeN (index N = 01 to 10)
UINT
●
Configuration - Counter timeout
1106 * (N-1) * 4
cfgCounterTimeoutN (index N = 01 to 10)
UINT
●