14
5)
Click Apply then OK.
6)
Press <ENTER> to wake the datalogger from sleep. The datalogger returns the power up
prompt:
Hello. Press "?" for Help.
*
Note: If no characters are received in 15 seconds the datalogger (non-networked) will
return to its low power sleep mode. Press <ENTER> to wake it again.
Note: When network commands are enabled and RS-485 is being used, the address must be
sent before the respective datalogger will respond. See Sections 4.20 through 4.24 for
additional information.
7)
Type ? then press <ENTER> to display the Help list. See Section 4 for detailed
information on all the commands listed.
All commands must be entered in capital letters!
*?
Command
Description
----------------------------------------------------------------
C
View current Clock
CSmm/dd/yy/hh:mm:ss Clock Set
DEFAULT
Load factory DEFAULT settings
DF Date Format (0=Julian, 1=month,day)
Dnnnnn Display nnnnn arrays from pointer
E End communications and go to sleep
Gnn/szzzz/sffff/soooo Gauge information, where;
nn = gauge type
szzzz = zero reading with sign
sffff = gauge factor with sign
soooo = offset with sign
IDdddddddddddddddd View current ID, set to ddddddddddddddd
LC
Select Linear Conversion
Ln/lllll/iii
View Log intervals/change n interval,
lllll=length,iii=iterations of interval
LD,LE Log intervals Disable, Enable
M,MD,ME Monitor status, Disable, Enable
MS
Memory Status
N Display Next time to read
NAddd
Network Address (1-256)
NS,ND,NE
Network Status, Disable, Enable
PC
Select Polynomial Conversion
Pnnnnn Position array pointer to nnnnn
R
Reset memory
RESET
Reset processor
RT
Readings total (8=8000 readings,
16=16000 readings)
SR
Synchronize readings (0=not synch’d,
1=synch’d)