BHK-MG (OPR) 032816
B-11
B.43
[SOURce:]CURRent:MODE? QUERY
CURR:MODE?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:MODE?
Long Form: [SOURce:]CURRent[:LEVel]:MODE?
Return value:
FIXED or LIST
Description:
Identifies active voltage mode.
Returns LIST while list is being executed. Returns FIXED while in
fixed (default) mode of operation. Related Commands: LIST commands. (See example, Figure B-3.)
B.44
[SOURce:]CURRent:PROTection[:LEVel] COMMAND
CURR:PROT
Syntax:
Short Form: [SOUR:]CURR:PROT[:LEV] <exp_value>
Long Form: [SOURce:]CURRent:PROTection[:LEVel] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Sets overcurrent protection level for power supply.
If the value is out of the acceptable overcurrent
range for the power supply model, error message -222,”Data out of range” is posted in the output
queue. If the power supply output exceeds the current protection level programmed, the power supply
circuit breaker trips. (See example, Figure B-4.)
B.45
[SOURce:]CURRent:PROTection[:LEVel]? QUERY
CURR:PROT?
Syntax:
Short Form: [SOUR:]CURR:PROT[:LEV]? {MIN | MAX}
Long Form: [SOURce:]CURRent:PROTection[:LEVel]? {MIN | MAX}
Return Value: <exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns value representing current protection level.
CURR:PROT? returns value set by
CURR:PROT. CURR:PROT? MAX returns maximum current protection value (see Table 1-2). This
value is determined at the factory and cannot be changed by the user. CURR:PROT? MIN returns the
minimum current protection value (always 0). (See example, Figure B-4.)
Description:
Returns the current value established by CURR:TRIG command.
(See example, Figure B-1.)
B.46
[SOURce:]CURRent:RANGe COMMAND
CURR:RANG
Syntax
:
Short Form: [SOUR:]CURR:RANG:LOW or [SOUR:]CURR:RANG:UPP
Long Form: [SOURce:]CURRent:RANGe:LOWer or [SOURce:]CURRent:RANGe:UPPer
Description:
Selects high scale or low scale Current range.
CURR:RANG:LOW selects Low scale,
CURR:RANG:UPP selects High scale. Low scale = Io
MAX
/10, High scale = Io
MAX
. This command
sets the output to OFF before executing the command, regardless of which range is currently active.
Refer to PAR. 3.2.10 for complete description.
B.47
[SOURce:]CURRent:RANGe? QUERY
CURR:RANG?
Syntax
:
Short Form: [SOUR:]CURR:RANG?
Long Form: [SOURce:]CURRent:RANGe?
Return Value: 0 or 1
Description:
Identifies current scale selected.
Returns 0 for low scale, 1 for high scale.
B.48
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] COMMAND
CURR:TRIG
Syntax:
Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP] <exp_value>
Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Programs current value to be transferred to output by *TRG commands.
Actual output current
will depend on load conditions. If the value exceeds the CURR:LIM[:HIGH] value, error message -
222,”Data out of range” is posted in output queue. Related Commands: CURR. (See example, Figure
B-1.)
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......