RC Commands
R&S
®
OSP
294
User Manual 1178.7100.02 ─ 05
DIAGnostic:SERVice:STESt:RESult?
Provides compatibility of remote control commands with legacy switch units
R&S
OSP120/130/150.
The command does
not
execute any self-test. It is implemented only to prevent errors
in existing remote control programs, when these programs cannot address the com-
mand.
Return values:
<result>
The result is always
"Passed"
, because the command does
not execute any self-test.
Example:
DIAG:SERV:STES:RES?
Return string:
"Passed"
Usage:
Query only
MMEM:LOAD:STATe
<dummy>,<filename>
Provides compatibility of remote control commands with legacy switch units
R&S
OSP120/130/150.
Equivalent to
.
All path filenames have the extension "
.path
". Do not enter the extension when speci-
fying a filename. A filename query does not return the extension.
For example, when you save the path file "
gen-pa_1
", it is saved as
"
gen-pa_1.path
". A query returns this filename as "
gen-pa_1
", only.
Setting parameters:
<dummy>
This parameter is required but not evaluated. It can have any
integer numerical value (no decimal places).
<filename>
String parameter to specify the name of the file to be loaded.
Example:
MMEM:LOAD:STAT "1","mypathconfigs"
Loads the file "
mypathconfigs
" from the flash memory into the
instrument’s internal volatile memory.
Usage:
Event
Manual operation:
See
MMEM:STORe:STATe
<dummy>,<filename>
Provides compatibility of remote control commands with legacy switch units
R&S
OSP120/130/150.
Equivalent to
.
Legacy System Commands from R&S