16.4.5 CRC0CNT: CRC0 Automatic Flash Sector Count
Bit
7
6
5
4
3
2
1
0
Name
Reserved
CRCCNT
Access
R
RW
Reset
0x0
0x00
SFR Page = 0xF; SFR Address: 0x97
Bit
Name
Reset
Access
Description
7:6
Reserved
Must write reset value.
5:0
CRCCNT
0x00
RW
Automatic CRC Calculation Block Count.
These bits specify the number of flash blocks to include in an automatic CRC calculation. The last address of the last flash
block included in the automatic CRC calculation is (CRCST+CRCCNT) x Block Size - 1. The block size is 1024 bytes.
16.4.6 CRC0FLIP: CRC0 Bit Flip
Bit
7
6
5
4
3
2
1
0
Name
CRC0FLIP
Access
RW
Reset
0x00
SFR Page = 0xF; SFR Address: 0x95
Bit
Name
Reset
Access
Description
7:0
CRC0FLIP 0x00
RW
CRC0 Bit Flip.
Any byte written to CRC0FLIP is read back in a bit-reversed order, i.e., the written LSB becomes the MSB. For example:
If 0xC0 is written to CRC0FLIP, the data read back will be 0x03.
If 0x05 is written to CRC0FLIP, the data read back will be 0xA0.
EFM8SB2 Reference Manual