Bit
Name
Reset
Access
Description
31:4
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
3
SCANSTOP
0
W1
Scan Sequence Stop
Write a 1 to stop scan sequence.
2
SCANSTART
0
W1
Scan Sequence Start
Write a 1 to start scan sequence.
1
SINGLESTOP
0
W1
Single Conversion Stop
Write a 1 to stop single conversion.
0
SINGLESTART
0
W1
Single Conversion Start
Write to 1 to start single conversion.
28.5.3 ADCn_STATUS - Status Register
Offset
Bit Position
0x008
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0
0
0
0
0
0
0
0
Access
R
R
R
R
R
R
R
R
Name
SCANDATASRC
SCANDV
SINGLEDV
WARM
SCANREFWARM
SINGLEREFWARM
SCANACT
SINGLEACT
Bit
Name
Reset
Access
Description
31:27
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
26:24
SCANDATASRC
0x0
R
Scan Data Source
This value indicates from which input channel the results in the ADCn_SCANDATA register originates.
Value
Mode
Description
0
CH0
Single ended mode: SCANDATA result originates from ADCn_CH0. Differential mode:
SCANDATA result originates from ADCn_CH0-ADCn_CH1
1
CH1
Single ended mode: SCANDATA result originates from ADCn_CH1. Differential mode:
SCANDATA result originates from ADCn_CH2_ADCn_CH3
2
CH2
Single ended mode: SCANDATA result originates from ADCn_CH2. Differential mode:
SCANDATA result originates from ADCn_CH4-ADCn_CH5
3
CH3
Single ended mode: SCANDATA result originates from ADCn_CH3. Differential mode:
SCANDATA result originates from ADCn_CH6-ADCn_CH7
4
CH4
SCANDATA result originates from ADCn_CH4
5
CH5
SCANDATA result originates from ADCn_CH5
6
CH6
SCANDATA result originates from ADCn_CH6
7
CH7
SCANDATA result originates from ADCn_CH7
23:18
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
17
SCANDV
0
R
Scan Data Valid
Scan conversion data is valid.
16
SINGLEDV
0
R
Single Sample Data Valid
Single conversion data is valid.
15:13
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
12
WARM
0
R
ADC Warmed Up
ADC is warmed up.
11:10
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
9
SCANREFWARM
0
R
Scan Reference Warmed Up
Summary of Contents for Giant Gecko EFM32GG