Digit collection timeout and calling
The default digit collection timeout (referred to as the inter digit timeout) is 10 seconds for
defined numbering plan tables. If at any point during the 10-second timeout sufficient digits
are collected, the call is made immediately.
Note:
If you apply a custom numbering plan with no rule entries, a digit collection timeout
of three seconds is enforced, regardless of how many digits are collected.
System-default dial plan rules
Rule ID
Pattern
system-default-1
^911n
system-default-2
^411
system-default-3
^[2-9][0-9]{6}
system-default-4
^1[2-9][0-9]{9}
system-default-5
^011[0-9]*T
system-default-6
^S[0-9]{2}
Parameters
You can provision the following parameters for creating a dial plan and adding rules:
Parameter
Description
Valid Options
Name*
Descriptive name for the dial plan.
text string up to 31 characters
Digit Short Timer(s)
Value to use that resolves an overlapping dial plan, where
you can enter additional digits if needed, causing a much
faster timeout and sending the digit string / INVITE much
quicker.
1-16
4 ‡
Digit Long Timer(s)
Value = 16 to use as the first digit timer (where dial tone will
time out) as well as in conditions where no dial plan match
has been found so more digits are required. Once a partial
match is found the long timer is no longer used.
4-20
16 ‡
ID
Index of dial plan rule.
1-100