XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-92
V2.1, 2008-08
SCU, V1.13
L1INTEN
5
rwh
Level Threshold 1 Interrupt Request Enable
This bit defines if an interrupt request trigger is
requested if the comparison check was successful.
When a check is successful is defined via bit
L1ALEV.
0
B
No interrupt is requested
1
B
An interrupt is requested
L1RSTEN
6
rwh
Level Threshold 1 Reset Request Enable
This bit defines if a reset request trigger is requested
if the comparison check was successful. When a
check is successful is defined via bit L1ALEV.
0
B
No reset is requested
1
B
An reset is requested
L1ASEN
7
rwh
Level Threshold 1 Asynchronous Action Enable
This bit defines if asynchronous action can be
performed if the comparison check was successful.
When a check is successful is defined via bit
L1ALEV.
0
B
No asynchronous actions are performed
1
B
Asynchronous actions can be performed
LEV2V
[10:8]
rwh
Level Threshold 2 Voltage
This bit field defines the level of threshold 2 that is
compared with the DMP_1 core voltage..
The values for the different configurations are listed
in the data sheet.
LEV2OK
11
rh
Level Threshold 2 Check Result
0
B
The core supply voltage of the DMP_1 is below
the Level Threshold 2 LEV2V
1
B
The core supply voltage of the DMP_1 is equal
or above the Level Threshold 2 LEV2V
L2ALEV
12
rwh
Level Threshold 2 Action Level
0
B
When the core supply voltage is below the
Level Threshold 2 voltage LEV2V the action
configured by bits L2INTEN, L2RSTEN, and
L2ASEN are requested
1
B
When the core supply voltage is equal or
above the Level Threshold 2 voltage LEV2V
the action configured by bits L2INTEN,
L2RSTEN, and L2ASEN are requested
Field
Bits
Type
Description