XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-186
V2.1, 2008-08
SCU, V1.13
DMP_1. In this way, the occurrence of a request is registered even when the DMP_1
domain, including the SCU, is powered down. The registered event can then be
processed when the SCU is in normal power mode again. Please note that the disable
control of register INTDIS also influences the sticky bit in register
(see
).
Which of the interrupt requests have a sticky flag in register DMPMIT is listed in
.
Note: When servicing an SCU interrupt request, make sure that all related request flags
are cleared after the identified request has been handled. To clear an interrupt
request that is stored in register DMPMIT, first clear the request source of the
source (e.g. WUTRG), clear the request within DMP_M via DMPMITCLR, and
then clear the request within DMP_1 via INTCLR.
6.9.2
SCU Interrupt Sources
The SCU receives the interrupt request lines listed in
Table 6-17
SCU Interrupt Overview
Source of Interrupt
Short Name Sticky Flag
in DMPMIT
Default Interrupt Node
Assignment in INTNPx
SWD OK 1 Interrupt
SWDI1
yes
6C
H
SWD OK 2 Interrupt
SWDI2
yes
6B
H
PVC_M OK 1 Interrupt
PVCMI1
yes
6C
H
PVC_M OK 2 Interrupt
PVCMI2
yes
6B
H
PVC_1 OK 1 Interrupt
PVC1I1
yes
6C
H
PVC_1 OK 2 Interrupt
PVC1I2
yes
6B
H
Wake-up Timer Interrupt
WUTI
yes
6B
H
Wake-up Trim Interrupt
WUI
yes
6C
H
Watchdog Timer Interrupt
WDTI
---
6B
H
GSC Interrupt
GSCI
yes
6C
H